11. ERROR CODES AND TROUBLESHOOTING
Please refer to other manual pages and wiring diagrams for location of fuses, terminal strips, etc.
11.1 ERROR CODES
ERROR
POSSIBLE CAUSE
REMEDY
Data/Schedule
Display E.r. 01.
Error Code #01.
Temp. Limit Switch Open /Overheated
Wait for the Temperature Limit
Switch to cool, or Check for
open circuit.
See section 4.3
and 4.5, and 5.4.6
.
Data/Schedule
Display E.r. 02.
Error Code #02.
FS1 AND FS7 both closed
Two Stage Operation not
allowed with FS7.
See section
4.3 and 4.4.
Data/Schedule
Display E.r. 03.
Error Code #03.
FS1 AND FS11 both closed.
Two Stage Operation not
allowed with FS11.
See section
4.3 and 4.4.
Data/Schedule
Display E.r. 04.
Error Code #04.
Attempt to weld while in Program Mode.
Return to Operate Mode.
See
section 2.1 and 6.
Data/Schedule
Display E.r. 05
Error Code #05.
FS1,FS3,FS7,FS11, closed to GND before
power on or before Emergency Stop is re-
closed after being opened.
Initiations must be open at
power on or after an ES
(Emergency Stop).
See section 1.1, 4.3, and 4.4
.
Data/Schedule
Display E.r. 06.
Error Code #06. Backstep or Retraction is
closed too long or at start of sequence.
Open TS1-TLS1/AUX1.
See section 4.3, 4.5, and 5.4.6
.
Data/Schedule
Display E.r. 07.
Error Code #07.
FS1 initiated while another seq. active.
Open TS1-FS1.
See section 4.3, 4.5, 5.4.3, 9.3.
Data/Schedule
Display E.r. 08.
Error Code #08.
FS3 initiated while another seq. active.
Open TS1-FS3.
See section 4.3, 4.5, 5.4.3, 9.3
.
Data/Schedule
Display E.r. 09.
Error Code #09.
FS7 initiated while another seq. active.
Open TS1-FS7.
See section 4.3, 4.5, 5.4.3, 9.3.
Data/Schedule
Display E.r. 10.
Error Code #10.
FS11 initiated while another seq. active.
Open TS1-FS11.
See section 4.3, 4.5, 5.4.3, 9.3.
Data/Schedule
Display E.r. 11.
Error Code #11.
Control BD. Control Relay problem.
Replace Control Board.
Data/Schedule
Display E.r. 12.
Error Code #12.
Control Bd. Hardware error.
Replace Control Board.
Data/Schedule
Display E.r. 13.
Error Code #13.
Full conduction detected
Change to higher Welding
Transformer Tap.
See section 5.4.10.
StockCheck.com
Summary of Contents for EN1000 series
Page 2: ...S t o c k C h e c k c o m ...
Page 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Page 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Page 121: ...Page 119 S t o c k C h e c k c o m ...
Page 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...