5. INTRODUCTION TO DATA PROGRAMMING
The EN1000 or EN1001 control is capable of
storing and accessing up to 50 unique welding
Schedules. This makes the EN1000 or
EN1001 particularly suitable for complex
welding operations, as well as automated
machinery. Programming allows the operator
to enter or change parameters of weld
SCHEDULES and the subsequent storing of
those parameters in non-volatile memory.
Basically, programming only requires
selecting
the FUNCTION to be programmed
(or modified),
changing
the data (with DATA
display/push-buttons) applicable to that
function, and then
entering
the desired
parameters into memory.
5.1 GENERAL PROGRAMMING
1.
Press and release the PROGRAM/OPERATE switch.
The PROGRAM LED will
light up and the OPERATE LED will turn off. Only in the PROGRAM MODE, the
control allows changes to existing data or entering new data. If an optional PROGRAM
LOCKOUT Key Switch is installed, see PROGRAM/ LOCKOUT following step 6.
2.
Select the SCHEDULE
to be entered or modified
by using the SCHEDULE push-
buttons
until the desired schedule number appears on the schedule display.
The left
push-button increments the display by ten, and the right push-button increments
the display by one
. When the maximum number is reached for either digit, that digit
resets to zero.
3.
Press the SELECT push-button to reach the required function.
Pressing and
holding the select button momentarily will move to the previous parameter.
The
FUNCTION INDICATOR LEDs show which function may be entered or modified, and
the DATA
DISPLAY shows the data stored in that function.
If the SELECT push-
button is pressed again, the function indicator will advance to the next function.
NOTE:
When the function indicator LED is advanced
one position past the SLOPE
COUNT function
, all function indicator LEDs will be off and the DATA DISPLAY
will show [
01
]; This indicates that the control is in the EXTENDED FUNCTION
mode and the extended functions can now be altered or viewed. See section 5.4
EXTENDED FUNCTIONS.
4. se the DATA push-buttons to change data.
The left button increments the data by ten,
and the right button increments the data by one.
When either digit reaches the
maximum, that digit resets to zero. See section 5.3 PROGRAMMING PARAMETERS.
Figure 5.1 Four digit DATA display
StockCheck.com
Summary of Contents for EN1000 series
Page 2: ...S t o c k C h e c k c o m ...
Page 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Page 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Page 121: ...Page 119 S t o c k C h e c k c o m ...
Page 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...