9.1.3 QUENCH TEMPER WITH CHAIN MODE
Schedules 03 and 04 are chained together to illustrate "Quench-Temper" operation. Schedule
03 performs the squeeze, weld and quench functions (using "Hold" for Quench), and 04
performs the temper and hold functions (using "Weld" for Temper). Valve output #3 is used.
The weld light gives a visual indication of the relative amplitude and duration of current
during weld and temper times.
SCHEDULE SQUEEZE
WELD/
HEAT
PERCENT
CURRENT
HOLD
OFF IMPULSES COOL
VALVE
MODE
CYCLE
MODE
SLOPE
MODE
SLOPE
COUNT
03
40
35
60
35
10
01
00
04
02
00
00
04
00
30
40
20
10
01
00
04
00
00
00
9.1.4 UP AND DOWN SLOPE WITH CHAIN MODE
Schedules 05, 06, 07 and 08 are chained together to illustrate up-down slope operation.
Schedule 05 performs the squeeze function and establishes the percent current at which the
up slope will begin (bottom current). Schedule 06 performs the weld function and sets the
up slope time. Schedule 07 sets the downslope time and the % current it starts from.
Schedule 08 establishes the percent current at which the downslope will end, and performs
the hold function. The number in the schedule display will change as the sequence
progresses from one schedule to the next. Valve output #1 is used for this example.
SCHEDULE SQUEEZE
WELD/
HEAT
PERCENT
CURRENT
HOLD
OFF IMPULSES COOL
VALVE
MODE
CYCLE
MODE
SLOPE
MODE
SLOPE
COUNT
05
40
00
10
00
00
01
00
01
02
00
00
06
00
20
60
00
00
01
00
01
02
01
20
07
00
00
60
00
00
01
00
01
02
02
22
08
00
00
05
20
10
01
00
01
00
00
00
StockCheck.com
Summary of Contents for EN1000 series
Page 2: ...S t o c k C h e c k c o m ...
Page 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Page 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Page 121: ...Page 119 S t o c k C h e c k c o m ...
Page 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...