Page 34
5. PRESS the ENTER push-button
to store the data from the DATA DISPLAY into
non-volatile memory
. As the enter key is pressed, the data display will blink and then
remain steady.
Repeat the steps described above as required. Any or all Functions may be programmed
depending on the final welding schedule or sequence required.
NOTE
:
Remember to press the ENTER push-button to complete a programming step
.
If the control is placed back in the operate mode, or if a different function is selected
before pressing the ENTER key,
the DATA shown in the display will be lost
. The
previous data will remain stored in memory.
6. When all the required FUNCTIONS for all required SCHEDULES have been
programmed, put the control in the OPERATE mode by pressing and releasing the
PROGRAM/OPERATE push-button switch, as in STEP 1, so that the OPERATE LED
turns on and the PROGRAM LED turns off.
5.2 PROGRAM LOCKOUT OPTIONS
5.2.1 PROGRAM LOCKOUT KEY OPTION
A PROGRAM LOCKOUT (25) key switch can be ordered as a factory installed option. It
may also be added later by the customer, if desired. To install the key switch, remove the
hole plug from the lower left corner of the front panel and mount the switch using the nut
provided. Plug the wires from the switch onto the mating two prong connector on the back
of the control circuit board.
Mounting the key switch will be easier if the front panel control circuit board assembly is
removed from the enclosure. Remove the four mounting screws from the front panel and lift
it off of the enclosure.
To put the control in the PROGRAM mode using the PROGRAM LOCKOUT Switch:
Rotate the key 45 degrees clockwise and hold; While holding the key in this position,
press and release the PROGRAM/OPERATE push-button, and then release the key.
The OPERATE LED will now turn off and the PROGRAM LED will turn on, indicating
programmability of all functions.
To put the control in the OPERATE mode:
Press the PROGRAM/OPERATE push-button again. The control will return to the
OPERATE Mode without the necessity of rotating the Key.
5.2.2 USING PROGRAM LOCKOUT KEY FOR ERROR CLEARING
Most errors except initiation, heatsink over temperature, and pressure errors (errors from
"#
to
#'
, and
%(
), may be cleared by pressing any push-button on the front panel. However, if
a program lockout switch is installed in the control, a key may be necessary for error clearing
voltage monitoring, current monitoring and several other non hardware related error codes
(all errors from
#)
t
to
%'
,
%)
,
3!O!
and
7!U!
) require that a key must be used to clear the error
condition and reset the control.
StockCheck.com
Summary of Contents for EN1000 series
Page 2: ...S t o c k C h e c k c o m ...
Page 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Page 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Page 121: ...Page 119 S t o c k C h e c k c o m ...
Page 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...