USING ANTI-TIEDOWN MODE, [
=!=!
] = [
"$
],
WITH S49 OPTION
If S49 Option board is present and connected to the Control Board, multiple schedule
selection is possible even in this mode. After power-up, the Control will automatically detect
S49 board, if board is present, and it will enable external binary schedule selection in ANTI-
TIEDOWN mode if [
=!=!
] = 02.
NOTE:
Starting with software revision 619016-002S, external binary schedule selection is
enabled in ANTI-TIEDOWN mode.
EXTERNAL BINARY SELECT, S49 OPTION [
=!=!
] = [
"%
]
In order to program this extended function parameter, [
=!=!
] = 03, the S49 option must be
present and connected to the Control Board. The option consists of a J4 ribbon cable an
additional PCB A/N 410329-004 with six binary schedule select inputs and Control board
A/N 600572-009 (EN1001) or 600541-009 (EN1000). These six dry contact closure
(approximately 24 VDC) inputs make all 49 schedules remotely available to the operator or
machine process control system.
In this mode, the initiation input, on TS1-FS3, and binary schedule select inputs, on S49
Option Board TS12-SS1-SS32, are dedicated as follows:
1. SELECT one of 49 schedules by an external device or operator acting on TS12-SS1
through TS12-SS32. See S49 Option Application Note 700182 for connection diagram
and corresponding schedule table.
2. INITIATE sequence beginning with the selected schedule using FS3.
NOTE:
In this mode, the operator cannot select schedules using the front panel in OPERATE
mode, and can only initiate sequence beginning with dialed schedule using FS3.
Function of the other two initiation inputs FS7 and FS11 is unchanged, i.e. FS7 is
dedicated to initiate only on schedule 10, and FS11 is dedicated to initiate only on
schedule 20.
NOTE:
If the binary selection inputs provide a decimal equivalent of 50 or above, the
Control will display schedule 49.
See Application Note
700182
for more information about S49 Option.
StockCheck.com
Summary of Contents for EN1000 series
Page 2: ...S t o c k C h e c k c o m ...
Page 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Page 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Page 121: ...Page 119 S t o c k C h e c k c o m ...
Page 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...