Software Release: [App: 02.09.10051.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042;
BTL: 02.09.10015.00]
Section 40
45
00-02-0939
2019-06-13
Stop Temperature
(Medium Security)
:
When the temperature rises to this set point, an auto stop will
occur.
Factory set to 32 F
.
Engage RPM.
In the Chipper Auto mode, the engine speed when the Feed Engage output will be activated.
Factory set to 2200 RPM.
Disengage RPM.
In the Chipper Auto mode, the engine speed when the Feed Disengage output will be
activated.
Factory set to 1800 RPM.
Disengage Delay.
The amount of time the Feed Disengage output is active.
Factory set to 50mSec.
Chipper Feed System.
Operation of the outputs.
Factory set to ON-OFF-ON.
Chipper type: ON-OFF-ON:
CHIPPER AUTO MODE
1.
(2) Control outputs, Engage and Disengage are off prior to start up.
2.
The engine is started manually using the MPC-10 / TEC-10 and throttled manually up to
the Engage RPM set point:
a. The Engage output turns on.
3.
If during normal operation, the engine speed drops to the Disengage RPM set point:
a. The Engage output turns off.
b. The Disengage output turns on.
c. The Disengage delay begins timing. This is the amount of time the disengage
(reverse) output is turned on for Chipper applications.
Factory set to 50 mS.
4.
When the Disengage delay expires:
a. The Disengage output turns off.
5.
When the engine speed rises to the Engage RPM set point:
a. The Engage output turns on.
CHIPPER MANUAL MODE (AUTOFEED OVERRIDE)
1.
The engine speed must be below the Disengage RPM set point to use the Autofeed
Override feature. An RPMs TOO HIGH warning will appear if the Autofeed Override
menu is accessed while the engine speed is higher than the Disengage RPM set point.
2.
The operator enters the password to access the main menu.
3.
Once in the main menu, the operator holds down the Enter button for 5 seconds.
4.
The Autofeed Override menu will appear in the Feed Off mode.
5.
For Feed Forward, the operator first presses and holds the Up Arrow, then presses and
holds the Enter button, holding both for 5 seconds:
6.
The Engage output turns on.
7.
The display will read Feed Forward.
8.
For Feed Reverse, the operator first presses and holds the Down Arrow, then presses
and holds the Enter button, holding both for 5 seconds:
9.
The Engage output turns off.
10.
The Disengage output turns on.
11.
The display will read Feed Reverse.
12.
For Feed Off, the operator presses and holds the Enter button for 5 seconds.
13.
If on, the Engage output turns off.
14.
If on, the Disengage output turns off.
15.
The display will read Feed Off.
16.
To exit the Autofeed Override feature, press and hold the Back button for 5 seconds.
This will return the controller to the main menu. Press the menu button to return to the
front display.