![Enovation Controls Murphy PowerCore MPC-10 Operation Manual Download Page 14](http://html.mh-extra.com/html/enovation-controls/murphy-powercore-mpc-10/murphy-powercore-mpc-10_operation-manual_2413864014.webp)
Software Release: [App: 02.09.10051.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042;
BTL: 02.09.10015.00]
Section 40
14
00-02-0939
2019-06-13
Hose Reel Irrigation
The Hose Reel Irrigation application houses the auto start functions and auto throttle methods
meant to be used on hose reel irrigation systems. The MPC-10 / TEC-10 allows for the hose reel
pump to auto start with several methods, including the Local Start key which may be the most
used in this application. The key feature of this application is the auto throttling method. This
feature allows the controller to manage the pump’s throttle in order to maintain a pressure in the
hose during irrigation.
The auto start functions and auto throttle methods to choose from are:
Auto Start/Stop Functions
•
Single Contact (requires a digital input for start and stop)
•
Local Start (Green Start key)
•
Two Contact Maintained (requires digital inputs for start and stop)
Auto Throttle Methods
•
Pressure Transducer (requires an analog input setting)
Frost Protection
The Frost Protection application houses the auto start functions and auto throttle methods meant
to be used on frost protection systems. This application allows for a wind machine, sprinkler or
other forms of frost protection using single contact or a temperature transducer.
The auto start functions and auto throttle methods to choose from are:
Auto Start/Stop Functions
•
Single Contact (requires a digital input for start and stop)
•
Temperature Transducer (requires an analog input setting)
Auto Throttle Methods
•
Running Loaded RPM
Chipper
The Chipper application houses the auto start functions and engage/disengage methods meant to
be used on Chippers. The operator can also choose between Chipper types, On-Off-On or
Dumping.
The functions available are:
Auto Start/Stop Functions
•
Local Start Key (Green Start key)
Engage RPM
Disengage RPM
Disengage Delay
Chipper Feed System
•
On-Off-On
•
Dumping