Safety
Information
Introduction
Product
Information
System
configuration
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
182
Unidrive SPM User Guide
www.controltechniques.com Issue Number: 3
13.5 Menu 5: Motor control
Figure 13-8 Menu 5 Open-loop logic diagram
2.01
Post ramp
reference
+
+
3.01
Slave frequency
demand
5.10
5.11
Motor rated
power factor
Motor number
of poles
5.02
Motor
voltage
5.03
Total motor
power (kW)
√
3 x V x I
Volt
L1 L2 L3
5.05
DC Bus
voltage
5.09
Motor rated
voltage
5.07
5.08
Motor rated
current
Motor rated
full load RPM
5.06
Motor rated
frequency
5.23
Voltage offset
5.17
Stator
resistance
5.15
Voltage boost
5.13
Dynamic V/f
select
Transient
inductance
4.02
4.20
4.17
4.01
Motor
current
magnitude
Motor magnetising
current
Motor active
current
Percentage
active current
Motormap
5.12
Autotune
5.24
5.14
Voltage
mode
5.01
Motor
frequency
5.04
Estimated
motor speed
Slip
compensation
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
Slip
compensation
enable
5.27
The parameters are all shown at their default settings
3.13
Frequency
slaving
enable
5.18
5.19
PWM
switching
frequency
High stability
space vector
modulation
Hertz
5.20
5.35
Quasi square
wave enable
Disable auto
switching
frequency
change
5.31
Voltage
controller
gain