Safety
Information
Introduction
Product
Information
System
configuration
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Unidrive SPM User Guide
237
Issue Number: 3 www.controltechniques.com
SM-I/O PELV parameters
*See trip SLX.Er,
Automation (I/O Expansion) module category
on page 286.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
x.01
Solutions Module ID
0 to 599
204
RO Uni
PT US
x.02
Solutions Module software version
0.00 to 99.99
RO Uni
NC PT
x.03
T5 digital I/O 3 state
OFF (0) or On (1)
RO Bit
NC PT
x.04
T6 digital I/O 4 state
OFF (0) or On (1)
RO Bit
NC PT
x.05
T7 digital input 5 state
OFF (0) or On (1)
RO Bit
NC PT
x.07
Relay 1 state
OFF (0) or On (1)
RO Bit
NC PT
x.08
Relay 2 state
OFF (0) or On (1)
RO Bit
NC PT
x.09
T3 digital I/O 1 state
OFF (0) or On (1)
RO Bit
NC PT
x.10
T4 digital I/O 2 state
OFF (0) or On (1)
RO Bit
NC PT
x.11
T3 digital I/O 1 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.12
T4 digital I/O 2 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.13
T5 digital I/O 3 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.14
T6 digital I/O 4 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.15
T7 digital input 5 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.16
Disable PELV User power
supply absent trip
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.17
Relay 1 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.18
Relay 2 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.19
Freeze flag
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.20
Digital I/O read word
0 to 255
RO Uni
NC PT
x.21
T3 digital I/O 1 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.22
T4 digital I/O 2 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.23
T5 digital I/O 3 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.24
T6 digital I/O 4 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.25
T7 digital input 5 destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.27
Relay 1 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni
PT US
x.28
Relay 2 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni
PT US
x.29
T6 digital I/O 4 output select
OFF (0) or On (1)
On (1)
RW Bit
US
x.31
T3 digital I/O 1 output select
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.32
T4 digital I/O 2 output select
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.33
T5 digital I/O 3 output select
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.38
Analog input 1 mode
0-20 (0), 20-0 (1), 4-20.tr (2), 20-4.tr (3),
4-20 (4), 20-4 (5)
0-20 (0)
RW Txt
US
x.39
Analog output mode
0-20 (0), 20-0 (1), 4-20 (2), 20-4 (3)
0-20 (0)
RW Txt
US
x.40
Analog input 1 level
0.0 to 100.0%
RO Bi
NC PT
x.41
Analog input 1 scaling
0.000 to 4.000
1.000
RW Uni
US
x.42
Analog input 1 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.43
Analog input 1 destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni DE
PT US
x.45
Analog output 2 scaling
0.000 to 4.000
1.000
RW Uni
US
x.47
Analog output 2 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni
PT US
x.48
Analog output 1 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW Uni
PT US
x.49
Analog output 1 scaling
0.000 to 4.000
1.000
RW Uni
US
x.50
Solutions Module error status*
0 to 255
RO Uni
NC PT
x.51
Solutions Module software sub-version
0 to 99
RO Uni
NC PT
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save