5.5.2 Remote mounting control master pod
Figure 5-11 Control master pod dimensions
The control master pod can be mounted remotely.
In order to expose the top mounting hole, the terminal covers need to be
removed. This is done by undoing the terminal cover screw highlighted
in Figure 5-11, and then removing the two plastic covers.
Use 2 x M6 screws to mount the control master pod to pre-drilled holes
using the dimensions shown in Figure 5-11.
N
The parallel cable for the control master pod is 2m long, as such it
should be mounted close to the appropriate power module.
5.6 Docking a Unidrive SPMC/U to an
SPMD
Docking a Unidrive SPMC/U to an SPMD allows the user to create an
AC input/AC output drive. The advantages of docking are:
•
Optimization of enclosure layout
•
Reduced cabling
Docking results in a reduction of heatsink air flow which has an effect on
the drive rating. Refer to section 14.1.1
Power and current ratings
(Derating for switching frequency and temperature)
on page 263.
5.6.1 Installing the docking kit
When mounting an SPMD and SPMC/U in a vertical plane, as shown in
Figure 5-17 on page 43 and Figure 5-21 on page 46, the following
docking kit (3470-0012) can be used to electrically connect the two
modules together.
Figure 5-12 Docking kit
The SPM interface bracket should be connected first, followed by the
SPM inverter to rectifier busbars, to the appropriate terminals as shown
in Figure 5-13.
111.6mm
(4.39in)
59.9mm
(2.36in)
35.4mm
(1.39in)
449.4mm
(17.69in)
160.4mm (6.31in)
390.2mm
(15.36in)
∅
5.5mm
(0.22in)
Terminal
cover
screw
Mounting
holes
In order to meet IP20, the control master pod should be
mounted to a solid surface to restrict access to the back of the
module.
CAUTION
NOTE
SPM interface
bracket
SPM inverter to rectifier
busbars