9.6.2 Detailed feedback device commissioning/start-up information
Standard quadrature encoder with or without commutation signals (A, B, Z or A, B, Z, U, V, W), or
Sincos encoder without serial communications
Encoder type
Pr
3.38
Ab
(0) for a quadrature encoder without commutation signals *
Ab.SErVO
(3) for a quadrature encoder with commutation signals
SC
(6) for a Sincos encoder without serial communications *
Encoder power supply voltage
Pr
3.36
5V
(0),
8V
(1) or
15V
(2)
If output voltage from the encoder is >5V, then the termination resistors must be disabled Pr
3.39
to 0
Encoder number of lines per
revolution
Pr
3.34
Set to the number of lines or sine waves per revolution of the encoder.
See section 9.6.3
Restriction of encoder number of lines per revolution
on page 135 for restrictions
on this parameter.
Encoder termination selection
(Ab or Ab.SErVO only)
Pr
3.39
0
= A, B, Z termination resistors disabled
1
= A, B termination resistors enabled and Z termination resistors disabled
2
= A, B, Z termination resistors enabled
Encoder error detection level
Pr
3.40
0
= Error detection disable
1
= Wire break detection on A, B and Z inputs enabled
2
= Phase error detection (Ab.SErVO only)
3
= Wire break detection on A, B and Z inputs and phase error detection (Ab.SErVO only)
Termination resistors must be enabled for wire break detection to operate
* These settings should only be used in closed loop vector mode, otherwise a phase offset test must be performed after every power up.
NOTE
Incremental encoder with frequency and direction (F and D), or
Forward and Reverse (CW and CCW) signals, with or without commutation signals
Encoder type
Pr
3.38
Fd
(1) for frequency and direction signals without commutation signals *
Fr
(2) for forward and reverse signals without commutation signals *
Fd.SErVO
(4) for a frequency and direction encoder with commutation signals
Fr.SErVO
(5) for forward and reverse signals with commutation signals
Encoder power supply voltage
Pr
3.36
5V
(0),
8V
(1) or
15V
(2)
If output voltage from the encoder is >5V, then the termination resistors must be disabled Pr
3.39
to 0
Encoder number of lines per
revolution
Pr
3.34
Set to the number of pulses per revolution of the encoder divide by 2.
See section 9.6.3
Restriction of encoder number of lines per revolution
on page 135 for restrictions
on this parameter.
Encoder termination selection
Pr
3.39
0
= F or CW, D or CCW, Z termination resistors disabled
1
= F or CW, D or CCW termination resistors enabled and Z termination resistors disabled
2
= For CW, D or CCW, Z termination resistors enabled
Encoder error detection level
Pr
3.40
0
= Error detection disable
1
= Wire break detection on F & D or CW & CCW, and Z inputs enabled
2
= Phase error detection (Fd.SErVO and Fr.SErVO only)
3
= Wire break detection on F & D or CW & CCW, and Z inputs and Phase error detection
(Fd.SErVO and Fr.SErVO only)
Termination resistors must be enabled for wire break detection to operate
* These settings should only be used in closed loop vector mode, otherwise a phase offset test must be performed after every power up.
NOTE