173
Reference Manual
00809-0100-4021, Rev GC
Section 4: F
OUNDATION
fieldbus Configuration
April 2014
Foundation™ fieldbus configuration
The following are the default tags for each of the possible Function blocks which display data on
the LCD display.
All other custom tags that are entered must be: numbers 0 - 9, letters A - Z, and/or spaces.
The following are the standard temperature units codes displayed on the LCD display.
All other custom units that are entered must be: numbers 0 - 9, letters A - Z, and/or spaces.
If the value of the process variable displayed has a bad or uncertain status, the following is
shown:
Sensor Drift Alert
“Error”
“SNSOR”
Hot Backup Active
“Error”
“SNSOR”
Thermocouple Degradation Alert
“Error”
“SNSOR”
Block name
LCD display bottom line
Transducer
“TRANS”
AI 1400
“AI 14”
AI 1500
“AI 15”
AI 1600
“AI 16”
PID 1700
“PID 1”
PID 1800
“PID 1”
ISEL 1900
“ISEL”
CHAR 2000
“CHAR”
ARITH 2100
“ARITH”
OSPL 2200
“OSPL”
Units
LCD display bottom line
Degrees C
“DEG C”
Degrees F
“DEG F”
Degrees K
“DEG K”
Degrees R
“DEG R”
Ohms
“OHMS”
Millivolts
“MV”
Percent (%)
Uses the percent symbol
Status
LCD display bottom line
Bad
“BAD”
Uncertain
“UNCTN”
Table 4-13. LCD Display Error Warning Descriptions
Message
LCD display
top line
LCD display
bottom line
Summary of Contents for Rosemount
Page 1: ...Reference Manual 00809 0100 4021 Rev GC April 2014 Rosemount 3144P Temperature Transmitter ...
Page 2: ......
Page 4: ...iv Reference Manual 00809 0100 4021 Rev GC Title Page April 2014 ...
Page 10: ...x Reference Manual 00809 0100 4021 Rev GC Table of Contents April 2014 Table of Contents ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev GC Section 2 Installation April 2014 Installation ...
Page 188: ...178 Reference Manual 00809 0100 4021 Rev GC Section 5 Maintenance April 2014 Maintenance ...
Page 250: ...Index 244 Reference Manual 00809 0100 4021 Rev GC Index April 2014 Index ...
Page 251: ......