3.25
PMW paper mill sleeve seal
Figure 3-33: PMW Threaded Pipe Mount Seal
A
B
A. Connection to transmitter
B. Diaphragm
3.25.1
Parts required for installation
The parts required to install the PMW paper mill seal will be defined here. Prior to
installation, you will need the following:
•
Torque wrench
•
Gasket (Emerson-supplied)
Cutting and welding equipment required if installing a new lower housing.
Verify the gasket material is appropriate for the application.
3.25.2
Installation steps
Follow these steps to install the PMW paper mill seal:
Procedure
1. Using the appropriate size hole saw, cut a hole in the process vessel to accept the
lower housing. The diameter for a lower housing with a heat isolator groove is 1.32-
in. (33,4 mm). The hole should produce a tight, uniform fit when coupled with the
lower housing.
2. Bevel the edge of the vessel hole to accept filler material (see
no larger than 37.5° is recommended; see ASME B16.25 for more details. Bevels can
be made on one or both sides of the tank. Do not grind or cut the bevel to a sharp
point. Attempt to leave a flat area. The flat area should be large enough to minimize
spud distortion but small enough so that tank weld requirements can be met.
Minimizing the bevel angle will decrease the amount of fill required during weld and
Reference Manual
Installation
00809-0100-4002
May 2020
Rosemount DP Level
67
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...