WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
6. Insert the EES hygienic flanged tank spud extended seal into the tank spud.
7. Using the previously installed bolts, attach the remote seal and gasket to the
process connection. Secure with nuts and hand-tighten.
8. Insert end-user-supplied bolts in the top two bolt holes of the flange on the remote
seal. Secure with nuts and hand-tighten.
9. Using a torque wrench on the nut, tighten the assembly in a cross-pattern to ensure
even installation (see
). The bolts should be torqued to the
applicable flange requirements. Required torque is a function of the gasket material
and surface treatment of the bolts and nuts which are end-user-supplied. Consider
leak checking the installation to ensure a robust connection.
3.19
VCS Tri Clamp in-line seal
Figure 3-26: VCS Tri Clamp In-line Seal
3.19.1
Parts required for installation
The parts required to install the VCS hygienic Tri Clamp seal will be defined here. Prior to
installation, you will need the following:
•
Clamps (end-user-supplied)
•
Gaskets (end-user-supplied)
•
Wrench (optional, depending on clamp)
Verify the gasket material is appropriate for the application. Ensure to use an EHEDG
approved gasket if EHEDG conformance is needed.
Reference Manual
Installation
00809-0100-4002
May 2020
Rosemount DP Level
57
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...