2
Remote Seal Systems
2.1
DP Level and remote seal system measurement
DP Level is a reliable measurement solution for measuring level, density, interface, or mass
of a process media inside a tank.
Remote seal system measurement is unaffected by agitation, foam, or internal obstacles.
Remote diaphragm seals extend limitations due to process conditions such as high and
low temperatures, corrosive processes, viscous mediums, and hygienic applications.
2.2
Terminology of system components
lists the basic components for seal assemblies.
Figure 2-1: Components on a Two- and Single-Seal Assembly
Two-seal assembly
Single-seal assembly
A
B
C
D
E
B
C
F
A. Pressure, differential pressure, or multivariable transmitter
B. Process flange
C. Remote diaphragm
D. Capillary
E. Flushing ring (optional)
F. Direct mount
Reference Manual
Remote Seal Systems
00809-0100-4002
May 2020
Rosemount DP Level