Procedure
1. Remove the protective cover from the diaphragm of the remote seal. Use extreme
caution during installation to ensure the diaphragm is not damaged.
2. Place the appropriate end-user-supplied gasket on the remote seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
3. Attach the remote seal and gasket to the process connection. Insert end-user-
supplied bolts, secure with nuts, and hand-tighten.
4. Using a torque wrench on the nut, tighten the assembly in a cross-pattern to ensure
even installation (see
). The bolts should be torqued to the
applicable flange requirements. Required torque is a function of the gasket material
and surface treatment of the bolts and nuts which are end-user-supplied. Consider
leak checking the installation to ensure a robust connection.
3.27
TFS wafer style In-line seal
Figure 3-36: TFS Wafer Style In-Line Seal
A
B
A. Connection to transmitter
B. Diaphragm
3.27.1
Parts required for installation
The parts required to install the TFS wafer style In-line seal will be defined here. Prior to
installation, you will need the following:
•
Torque wrench
•
Mounting hardware (end-user-supplied)
•
Gasket (end-user-supplied)
Installation
Reference Manual
May 2020
00809-0100-4002
70
Rosemount DP Level
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...