WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
2. Align that end of the WFW flow-thru flanged seal flush with the process flange.
3. Insert end-user-supplied bolts, secure with nuts, and hand-tighten.
4. Place the second appropriate end-user-supplied gasket for the application on the
other end of the lower housing flange.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
5. Align that end of the WFW flow-thru flanged seal flush with the process flange.
6. Insert end-user-supplied bolts, secure with nuts, and hand-tighten
7. Using a torque wrench on the nut, tighten the assembly in a cross-pattern to ensure
even installation (see
). The bolts should be torqued to the
applicable flange requirements. Required torque is a function of the gasket material
and surface treatment of the bolts and nuts which are end-user-supplied. Consider
leak checking the installation to ensure a robust connection.
8. Remove the protective cover from the diaphragm of the remote seal. Use extreme
caution during installation to ensure the diaphragm is not damaged.
9. Assemble the remote seal, Emerson-supplied gasket, and lower housing. Failure to
properly install the gasket may cause process leaks, which can result in death or
serious injury.
10. Install the bolts in a cross pattern and hand-tighten.
11. Using a torque wrench on the bolt, tighten the assembly in a cross-pattern to
). The bolts should be torqued to 180
in-lb (20 N-m) with stainless or carbon steel bolts. Consider leak checking the
installation to ensure a robust connection.
Reference Manual
Installation
00809-0100-4002
May 2020
Rosemount DP Level
73
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...