Verify the gasket material is appropriate for the application.
Inspect bolts to ensure the material is compatible with industry standards per the
application such as ASME PCC-1.
3.27.2
Installation steps
Follow these steps to install the TFS wafer style In-line seal on an existing flanged process
connection:
Procedure
1. Place the appropriate end-user-supplied gasket for the application on one end of
the remote seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
2. Align that end of the TFS wafer style In-line seal flush with the process flange.
3. Insert end-user-supplied bolts, secure with nuts, and hand-tighten
4. Place the second appropriate end-user-supplied gasket for the application on the
other end of the remote seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
5. Align that end of the TFS wafer style In-line seal flush with the process flange.
6. Insert end-user-supplied bolts, secure with nuts, and hand-tighten.
7. Using a torque wrench on the nut, tighten the assembly in a cross-pattern to ensure
even installation (see
). The bolts should be torqued to the
applicable flange requirements. Required torque is a function of the gasket material
and surface treatment of the bolts and nuts which are end-user-supplied. Consider
leak checking the installation to ensure a robust connection.
Reference Manual
Installation
00809-0100-4002
May 2020
Rosemount DP Level
71
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...