3.19.2
Installation steps
Follow these steps to install the VCS hygienic Tri Clamp seal:
Procedure
1. Place the appropriate end-user-supplied gasket for the application on the remote
seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
2. Align one end of the VCS hygienic Tri Clamp seal flush with the process piping.
3. Attach the clamp and tighten to manufacturer's specifications (wrench might be
required depending on clamp style).
4. Place the second appropriate end-user-supplied gasket for the application on the
remote seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
5. Align the other end of the VCS hygienic Tri Clamp seal with the process piping.
6. Attach the clamp and tighten to manufacturer's specifications (wrench might be
required depending on clamp style).
Note
EHEDG requirement on T-stub installations: the length (L) divided by the diameter
(D) of the tee is to be less than 1 (i.e. L /D < 1).
D
L
Installation