Parameter
12.014
Variable Selector 1 Source 2 Scaling
Short description
Defines the scaling for the 2nd input for variable selector 1
Mode
Open
‑
Loop
Minimum
-4.000
Maximum
4.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
3
Coding
RW
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.015
Variable Selector 1 Control
Short description
Defines the control for variable selector 1
Mode
Open
‑
Loop
Minimum
0.00
Maximum
100.00
Default
0.00
Units
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.016
Variable Selector 1 Enable
Short description
Enables variable selector 1
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
1
Units
Type
1 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW, BU
See
Variable Selector 1 Source 1
(12.008) for more details.
Variable Selector 1 Enable
(12.016) and
Variable Selector 2 Enable
(12.036) have a default of 1 so that if these parameters are not used the variable
selectors will still function.
Parameter
12.023
Threshold Detector 2 Source
Short description
Defines the source paramter for threshold detector 2
Mode
Open
‑
Loop
Minimum
0.000
Maximum
59.999
Default
0.000
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
See
Threshold Detector 1 Output
(12.001).
Parameter
12.024
Threshold Detector 2 Level
Short description
Defines the reference level for threshold detector 2
Mode
Open
‑
Loop
Minimum
0.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Threshold Detector 1 Output
(12.001).
Parameter
12.025
Threshold Detector 2 Hysteresis
Short description
Defines the hysteresis for threshold detector 2
Mode
Open
‑
Loop
Minimum
0.00
Maximum
25.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Threshold Detector 1 Output
(12.001).
224
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...