between 5 and 7 it indicates that the negative power device in a phase has failed (5 = U, 6 = V, 7 = W).
The "Phases" test requires that 1/2 rated motor current flows to indicate that the phase is connected. The "Devices" test only requires 1/8 of rated current,
and so it produces much less acoustic noise on starting. In either mode the tests take approximately 50ms. The "Devices" test is the preferred test as it
tests all the power devices and produces less acoustic noise. The "Phases" test is provided for legacy reasons.
Parameter
06.060
Standby Mode Enable
Short description
Set to 1 enable standby mode
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
If
Standby Mode Enable
(06.060) = 1 then the drive will go into the standby power state whenever
Drive Active
(10.002) = 0 with a delay of 30s. In this
state the LED on the front of the drive flashes 0.5s on and 5s off, the drive cannot be enabled and the following actions are taken as defined by the
Standby Mode Mask
(06.061). Actions are enabled by setting the appropriate bit to 1. Once standby mode has become active it will remain active, even if
an attempt is made subsequently to enable the drive, until
Standby Mode Enable
(06.060) is set to 0.
Standby Mode Mask
(06.061) bits
Action
0
Turn off the drive position feedback power supply.
On leaving standby mode the drive position feedback
interfaces will be re-initialised.
1
Turn off the power supply to a keypad fitted to the
drive.
2
Turn off the drive 24V output.
3
Request that the option module in option slot 1 to go
into the standby power mode
4
Request that the option module in option slot 2 to go
into the standby power mode
5
Request that the option module in option slot 3 to go
into the standby power mode
6
Request that the option module in option slot 4 to go
into the standby power mode
Parameter
06.061
Standby Mode Mask
Short description
Mode
Open
‑
Loop
Minimum
0
(Display: 0000000)
Maximum
127
(Display: 1111111)
Default
0
(Display: 0000000)
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Binary
Decimal Places
0
Coding
RW
See
Standby Mode Enable
(06.060).
Parameter
06.065
Standard Under Voltage Threshold
Short description
Defines the standard under voltage threshold
Mode
Open
‑
Loop
Minimum
−VM_STD_UNDER_VOLTS
Maximum
VM_STD_UNDER_VOLTS
Default
See exceptions below
Units
V
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, VM, RA
Voltage
Default Value
200V
175
400V
330
575V
435
690V
435
Under-voltage and power supply control
98
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...