Acceleration Rate Select Bit 2
(02.034)
Acceleration Rate Select Bit 1
(02.033)
Acceleration Rate Select Bit 0
(02.032)
Acceleration rate
selected
0
0
0
Acceleration Rate 1
(02.011)
0
0
1
Acceleration Rate 2
(02.012)
0
1
0
Acceleration Rate 3
(02.013)
0
1
1
Acceleration Rate 4
(02.014)
1
0
0
Acceleration Rate 5
(02.015)
1
0
1
Acceleration Rate 6
(02.016)
1
1
0
Acceleration Rate 7
(02.017)
1
1
1
Acceleration Rate 8
(02.018)
If
Acceleration Rate Selector
(02.010) = 9 the acceleration rate is selected based on the value of
Preset Selected Indicator
(01.050), i.e. 1
selects
Acceleration Rate 1
(02.011), 2 selects
Acceleration Rate 2
(02.012), etc.
Parameter
02.011
Acceleration Rate 1
Short description
Defines the acceleration rate present in acceleration rate 1
Mode
Open
‑
Loop
Minimum
−VM_ACCEL_RATE
Maximum
VM_ACCEL_RATE
Default
20.0
Units
s
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
1
Coding
RW, VM
Acceleration Rate 1
(02.011) to
Acceleration Rate 8
(02.018) can be selected to define the linear ramp rate. The acceleration rate applies when the
frequency/speed is changing away from zero.
Selecting a ramp rate that has been set to zero in Open-loop mode disables the ramp system so that the
Post Ramp Reference
(02.001) follows the
Pre-ramp Reference
(01.003) without any delay for acceleration or deceleration. It should be noted that this also disables the standard ramp d.c. link
voltage controller and the frequency based current limits.
The units of
Acceleration Rate 1
(02.011) to
Acceleration Rate 8
(02.018) are s / Ramp rate frequency or s / Ramp rate speed. See
Ramp Rate Units
(02.039) for the definition of Ramp rate frequency and Ramp rate speed.
Parameter
02.012
Acceleration Rate 2
Short description
Defines the acceleration rate present in acceleration rate 2
Mode
Open
‑
Loop
Minimum
−VM_ACCEL_RATE
Maximum
VM_ACCEL_RATE
Default
20.0
Units
s
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
1
Coding
RW, VM
See
Acceleration Rate 1
(02.011).
Parameter
02.013
Acceleration Rate 3
Short description
Defines the acceleration rate present in acceleration rate 3
Mode
Open
‑
Loop
Minimum
−VM_ACCEL_RATE
Maximum
VM_ACCEL_RATE
Default
20.0
Units
s
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
1
Coding
RW, VM
See
Acceleration Rate 1
(02.011).
Parameter
02.014
Acceleration Rate 4
Short description
Defines the acceleration rate present in acceleration rate 4
Mode
Open
‑
Loop
Minimum
−VM_ACCEL_RATE
Maximum
VM_ACCEL_RATE
Default
20.0
Units
s
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
1
Coding
RW, VM
42
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...