![Emerson Powerdrive F300 Reference Manual Download Page 30](http://html.mh-extra.com/html/emerson/powerdrive-f300/powerdrive-f300_reference-manual_102547030.webp)
resolution than other frequency parameters in Open-loop mode as this prevents loss of resolution when an analogue input is routed to this parameter with a
typical drive output frequency range.
See
Analog Reference 1
(01.036).
Parameter
01.038
Percentage Trim
Short description
Defines the value of the reference trim as a percentage
Mode
Open
‑
Loop
Minimum
-100.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit Volatile
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW, NC
See
Reference Offset Select
(01.009).
Parameter
01.039
Speed Feed-forwards
Short description
Displays the value of the speed feed-forwards used by the standard motion controller
Mode
Open
‑
Loop
Minimum
−VM_SPEED_FREQ_REF
Maximum
VM_SPEED_FREQ_REF
Default
Units
Type
32 Bit Volatile
Update Rate
4ms write
Display Format
Standard
Decimal Places
1
Coding
RO, VM, ND, NC, PT
Speed Feed-forwards
(01.039) can be used by the Standard Motion Controller (Menu 13) to provide a speed feed-forwards term which uses the drive ramp
system (Menu 2) to provide a speed profile. The speed feed-forwards is enabled with
Speed Feed-forwards Select
(01.040), which is controlled directly by
the Standard Motion Controller.
Parameter
01.040
Speed Feed-forwards Select
Short description
Indicates if the speed feed-forwards is being used by the standard motion controller
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
See
Speed Feed-forwards
(01.039).
Parameter
01.041
Reference Select Flag 1
Short description
Defines which reference is selected by the drive
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW, NC
See
Reference Selector
(01.014).
Parameter
01.042
Reference Select Flag 2
Short description
Defines which reference is selected by the drive
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW, NC
See
Reference Selector
(01.014).
Parameter
01.043
Reference Select Flag 3
Short description
Defines which reference is selected by the drive
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW, NC
See
Reference Selector
(01.014).
30
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...