Parameter
11.091
Additional Identifier Characters 1
Short description
Displays the additional identifier characters
Mode
Open
‑
Loop
Minimum
-2147483648
Maximum
2147483647
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
String
Decimal Places
0
Coding
RO, ND, NC, PT
See
Product Identifier Characters
(11.064).
Parameter
11.092
Additional Identifier Characters 2
Short description
Displays the additional identifier characters
Mode
Open
‑
Loop
Minimum
-2147483648
Maximum
2147483647
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
String
Decimal Places
0
Coding
RO, ND, NC, PT
See
Product Identifier Characters
(11.064).
Parameter
11.093
Additional Identifier Characters 3
Short description
Displays the additional identifier characters
Mode
Open
‑
Loop
Minimum
-2147483648
Maximum
2147483647
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
String
Decimal Places
0
Coding
RO, ND, NC, PT
See
Product Identifier Characters
(11.064).
Parameter
11.095
Number Of Rectifiers Detected
Short description
Number Of Rectifiers Detected
Mode
Open
‑
Loop
Minimum
0
Maximum
9
Default
Units
Type
8 Bit Volatile
Update Rate
Background Write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
Indicates how many controlled rectifiers connected to the drive have been detected. See
Number Of Rectifiers Expected
(11.096).
Parameter
11.096
Number Of Rectifiers Expected
Short description
Number of rectifiers expected on each power stage
Mode
Open
‑
Loop
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit User Save
Update Rate
Background Read
Display Format
Standard
Decimal Places
0
Coding
RW
Number Of Rectifiers Expected
(11.096) defines how many controlled rectifiers are expected on each power module. Within a complete drive with a
diode input stage there are no controlled rectifiers. Within a complete drive with a controlled rectifier input stage there is one controlled rectifier. For a
drive where external rectifiers are used the system can register up to nine controlled rectifiers. If
Number Of Rectifiers Expected
(11.096) = 0 then the
rectifier monitoring system is disabled and the drive does not check how many controlled rectifiers are present. This is the default setting and should be
used for complete drives with internal rectifiers because the monitoring function is not necessary. If
Number Of Rectifiers Expected
(11.096) is set to a
non-zero value a check is made to ensure that at least this number of external rectifiers are connected to each power module. If there are less external
rectifiers than defined by
Number Of Rectifiers Expected
(11.096) then a
Configuration
is initiated with the sub-trip indicating how many rectifers should
be present. See
Trip 0
(10.020).
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
217
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...