2
31
- 1, but if the time is 0 a value of 1 is written.
Trip Time Identifier
(10.103) can be used to determine when a new trip has occurred as the value will
change (unless there were exactly 2
32
ms between trips) and will be non-zero.
Parameter
10.104
Active Alarm
Short description
Shows the value of the active alarm
Mode
Open
‑
Loop
Minimum
0
Maximum
12
Default
Units
Type
8 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, TE, ND, NC, PT, BU
Value
Text
0
None
1
Brake Resistor
2
Motor Overload
3
Ind Overload
4
Drive Overload
5
Auto Tune
6
Limit Switch
7
Fire Mode
8
Low Load
9
Option Slot 1
10
Option Slot 2
11
Option Slot 3
12
Option Slot 4
If there is no alarm then
Active Alarm
(10.104) = 0. If one alarm is active then
Active Alarm
(10.104) shows the value of the alarm. If more than one
alarm is active then
Active Alarm
(10.104) shows the active alarm with the lowest value. The strings from this parameter are also used by the basic
keypad to provide the status display text except for option slot warnings where the option module may supply the string.
Parameter
10.105
Hand Off Auto State
Short description
Shows the state of the hand/off/auto system
Mode
Open
‑
Loop
Minimum
0
Maximum
3
Default
Units
Type
8 Bit Power Down Save
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, TE, ND, NC, PT
Value
Text
0
Not Active
1
Off
2
Hand
3
Auto
See
Hand/Off/Auto Operating Mode
(01.052) for details of the hand/off/auto system.
Hand Off Auto State
(10.105) shows the state of this system and is
used at power-up to restore the previous state if required.
Parameter
10.106
Potential Drive Damage Conditions
Short description
Indicates that the user has put the drive in a condition that could potentially damage the drive
Mode
Open
‑
Loop
Minimum
0
(Display: 0000)
Maximum
15
(Display: 1111)
Default
Units
Type
8 Bit Power Down Save
Update Rate
Background write
Display Format
Binary
Decimal Places
0
Coding
RO, ND, NC, PT, BU
The bits in
Potential Drive Damage Conditions
(10.106)
are set under the conditions shown in the table below to indicate that the user has put the
drive in a condition that could potentially damage the drive. The bits in this parameter cannot be cleared by users.
192
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Summary of Contents for Powerdrive F300
Page 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Page 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Page 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Page 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Page 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...