4
Configure process measurement
Topics covered in this chapter:
•
Configure mass flow measurement
•
Configure volume flow measurement for liquid applications
•
Configure gas standard volume (GSV) flow measurement
•
•
•
Configure temperature measurement
4.1
Configure mass flow measurement
The mass flow measurement parameters control how mass flow is measured and reported.
The mass flow measurement parameters include:
•
Mass Flow Measurement Unit
•
Flow Damping
•
Mass Flow Cutoff
4.1.1
Configure
Mass Flow Measurement Unit
ProLink III
Device Tools
>
Configuration
>
Process Measurement
>
Flow
Overview
Mass Flow Measurement Unit
specifies the unit of measure that will be used for the mass flow
rate. The unit used for mass total and mass inventory is derived from this unit.
Procedure
Set
Mass Flow Measurement Unit
to the unit you want to use.
The default setting for
Mass Flow Measurement Unit
is
g/sec
(grams per second).
Options for
Mass Flow Measurement Unit
The transmitter provides a standard set of measurement units for
Mass Flow Measurement
Unit
, plus one user-defined special measurement unit. Different communications tools may
use different labels for the units.
Configure process measurement
Configuration and Use Manual
17
Summary of Contents for Micro Motion LNG Series
Page 1: ...Configuration and Use Manual MMI 20032809 Rev AA February 2017 Micro Motion LNG Series Meters ...
Page 6: ...Contents iv Micro Motion LNG Series Meters ...
Page 8: ...Getting Started 2 Micro Motion LNG Series Meters ...
Page 12: ...Before you begin 6 Micro Motion LNG Series Meters ...
Page 18: ...Quick start 12 Micro Motion LNG Series Meters ...
Page 20: ...Configuration and commissioning 14 Micro Motion LNG Series Meters ...
Page 50: ...Configure device options and preferences 44 Micro Motion LNG Series Meters ...
Page 56: ...Integrate the meter with the control system 50 Micro Motion LNG Series Meters ...
Page 58: ...Complete the configuration 52 Micro Motion LNG Series Meters ...
Page 60: ...Operations maintenance and troubleshooting 54 Micro Motion LNG Series Meters ...
Page 74: ...Measurement support 68 Micro Motion LNG Series Meters ...
Page 94: ...Using ProLink III with the transmitter 88 Micro Motion LNG Series Meters ...
Page 98: ...Default values and ranges 92 Micro Motion LNG Series Meters ...
Page 99: ...Default values and ranges Configuration and Use Manual 93 ...