eloProg - Vers. 1.0
79
"Sequential" MUTING
The MUTING operator with "Sequential" logic
performs muting of the input signal through sensor
inputs S1, S2, S3 and S4.
Î
Preliminary condition: The Muting cycle can
only start if all the sensors are 0 (FALSE) and
the inputs are 1 (TRUE) (barrier free).
Parameters
Timeout (sec)
: Sets the time, between 10 secs and
unlimited, within which the Muting cycle must end.
If the cycle is not complete at the end of this time,
Muting is immediately discontinued.
Enable
: If selected it enables the possibility of
enabling or not enabling the Muting function.
Otherwise the Muting function is always enabled.
There are two Enable modes: Enable/Disable and Enable Only. If Enable/Disable is selected the
Muting cycle cannot start if Enable is fixed at 1 (TRUE) or 0 (FALSE) but is only activated with a
rising edge. To disable muting, set Enable to 0 (FALSE). In this mode the falling edge disables
Muting regardless of the condition. If Enable Only is selected Muting cannot be disabled but
Enable must be set to 0 (FALSE) in order to enable a new rising edge for the next Muting cycle.
Direction
: The order in which the sensors are occupied can be set. If set to BIDIR they can be
occupied in both directions, from S1 to S4 and from S4 to S1, if set to UP they can be occupied
from S1 to S4 and if set to DOWN from S4 to S1.
Muting Close
: There are two types, CURTAIN and SENSOR. If you select CURTAIN muting closes
when the input signal rises, if you select SENSOR it closes when the last sensor has been cleared.
Select CURTAIN
S1
S2
Input
S3
S4
Muting
0 0 1 0 0 0
1 0 1 0 0 0
1 1 1 0 0 1
1 1 X 0 0 1
1 1 X 1 0 1
1 1 X 1 1 1
0 1 X 1 1 1
0 0 0 1 1 1
0 0 1 1 1 0
0 0 1 0 1 0
0 0 1 0 0 0
Select SENSOR
S1
S2
Input
S3
S4
Muting
0 0 1 0 0 0
1 0 1 0 0 0
1 1 1 0 0 1
1 1 X 0 0 1
1 1 X 1 0 1
1 1 X 1 1 1
0 1 X 1 1 1
0 0 0 1 1 1
0 0 1 1 1 1
0 0 1 0 1 0
0 0 1 0 0 0