eloProg - Vers. 1.0
485EPR02
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1 24VDC
-
24VDC power supply
-
4 GND
-
0VDC power supply
-
5 OSSD1_A
Input
Control
ZONE 1
PNP active high
6 OSSD1_B
Input
7 FBK_K1_K2_1
Output
Feedback K1K2
ZONE 1
N.C.
9 A_NC1
Output
NC contact
ZONE 1
10 B_NC1
Output
13 A_NO11
Output
NO1 contact
ZONE
1
14 B_NO11
Output
15 A_NO12
Output
NO2 contact
ZONE 1
16 B_NO12
Output
Table 9
EXAMPLE OF CONNECTION OF eloProg TO THE MACHINE CONTROL SYSTEM
Figure 4
CHECKLIST AFTER INSTALLATION
The eloProg system is able to detect the faults that occur in each own module.
Anyway to have the system perfect perform the following checks at start up and at least every one
year:
1.
Operate a complete system TEST (see "TESTING the system")
2.
Verify that all the cables are correctly inserted and the terminal blocks well screwed.
3.
Verify that all the leds (indicators) light on correctly.
4.
Verify the positioning of all the sensors connected to eloProg.
5.
Verify the correct fixing of eloProg to the Omega rail.
6.
Verify that all the external indicators (lamps) work properly.
After installation, maintenance and after any eventual configuration change perform a System
TEST as described in the paragraph
"TESTING the system" at page 53.