17
485EPA02
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1 24VDC
-
24VDC power supply
-
2 NODE_SEL1
Input
Node selection
Input
(
"type B"
according to EN 61131-2 )
3 NODE_SEL2
Input Input
(
"type B"
according to EN 61131-2 )
4 GND
-
0VDC power supply
-
5 OSSD1_A
Output
safety output 1
PNP active high
6 OSSD1_B
Output
PNP active high
7 RESTART_FBK1
Input
Feedback/Restart 1
Input according to EN 61131-2
8 OUT_STATUS1
Output
Condition of outputs 1A/1B
PNP active high
9 OSSD2_A
Output
safety output 2
PNP active high
10 OSSD2_B
Output
PNP active high
11 RESTART_FBK2
Input
Feedback/Restart 2
Input according to EN 61131-2
12 OUT_STATUS2
Output
Condition of outputs 2A/2B
PNP active high
13 24VDC
-
24VDC power supply
OSSD1/2 power supply
14 n.c.
- -
-
15 GND
-
0VDC power supply
-
16 n.c.
- -
-
Table 7
485EPR04
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1 24VDC
-
24VDC power supply
-
4 GND
-
0VDC power supply
-
5 OSSD1_A
Input
Control
ZONE 1
PNP active high
6 OSSD1_B
Input
7 FBK_K1_K2_1
Output
Feedback K1K2
ZONE 1
N.C.
9 A_NC1
Output
NC contact
ZONE 1
10 B_NC1
Output
13 A_NO11
Output
NO1 contact
ZONE 1
14 B_NO11
Output
15 A_NO12
Output
NO2 contact
ZONE 1
16 B_NO12
Output
11 A_NC2
Output
NC contact
ZONE 2
12 B_NC2
Output
17 OSSD2_A
Input
Control
ZONE 2
PNP active high
18 OSSD2_B
Input
19 FBK_K1_K2_2
Output
Feedback K1K2
ZONE 2
N.C.
21 A_NO21
Output
NO1 contact
ZONE 2
22 B_NO21
Output
23 A_NO22
Output
NO2
contact
ZONE 2
24 B_NO22
Output
Table 8