eloProg - Vers. 1.0
63
Î
WARNING: If the Enabled Reset is active, a consecutive Input has to be used. Example:
Input 1 is used for the functional block, then Input 2 has to be used for the Reset Input.
Output test
: This is used to select which test output are to be sent to the photocell test input. This
additional test makes it possible to detect and manage any short-circuits between the lines. One
test signal is mandatory and can be chosen among the four possible test output signals: Test
Output 1 ÷ Test Output 4.
Test at start-up
: If selected this enables the test at start-up of the external component. This test is
performed by opening the mobile guard or safety gate to run a complete function test and enable
the output. This test is only requested at machine start-up (when the unit is switched on).
Filter (ms)
: This is used to filter the signals coming from the external contacts. The filter can be
configured to between 3 and 250 ms and eliminates any bouncing on the contacts. The length of
the filter affects the calculation of the unit's total response time.
Object description
: This allows a description of the component's function to be entered. The text is
displayed in the top part of the symbol.