eloProg - Vers. 1.0
68
Filter (ms)
: This is used to filter the signals coming from the safety light curtain. The filter can be
configured to between 3 and 250 ms and eliminates any bouncing on the contacts. The length of
the filter affects the calculation of the unit's total response time.
Object description
: This allows a description of the component's function to be entered. The text is
displayed in the top part of the symbol.
COMMENTS
This allows a description to be entered and placed in
any point of the diagram.
OPERATOR FUNCTION BLOCKS
All the input of these operators could be inverted (logical NOT). It could be done clicking with the
right mouse key on the input to be inverted. A little circle will be showed on the inverted input. To
cancel the inversion, simply click another time on the same input pin.
Î
The maximum number of user blocks is 32.
LOGICAL OPERATORS
AND
Logical AND returns an output of 1 (TRUE) if all
the inputs are 1 (TRUE).
In
1
In
2
In
x
Out
0 0 0 0
1 0 0 0
0 1 0 0
1 1 0 0
0 0 1 0
1 0 1 0
0 1 1 0
1 1 1 1
Parameters
Number of inputs
: this is used to set between 2 and 8 inputs.