eloProg - Vers. 1.0
74
MONOSTABLE
The MONOSTABILE operator generates a level 1
(TRUE) output activated by the rising edge of the
input and remains in this condition for the set
time.
Parameters
Time
: The delay can be set to between 10 ms
and 1093.3 s.
Rising edge
: If selected, the output is set to 1 (TRUE) on the input signal's rising edge where it
remains for the set time, which can be extended for as long as the input stays at 1 (TRUE).
In
Out
T T
T
If not selected the logic is inverted, the output is set to 0 (FALSE) on the input signal's falling edge,
where it remains for the set time, which can be extended for as long as the input stays at 0
(FALSE).
In
Out
T T
T
Retriggerable
: If selected the time is reset each time the input status changes.