eloProg - Vers. 1.0
80
Blind Time
:
Only with Muting Close=Curtain, blind time
is enabled if you know that after the
complete transition of the pallet (muting cycle close) some protruding objects could still occupy the
light curtain and send the input to 0 (FALSE). During blind time the input remains 1 (TRUE). Blind
Time can range from 250 msecs to 1 second.
MUTING “T”
The MUTING operator with “T” logic
performs
muting of the input signal through sensor
inputs
S1 and S2.
Î
Preliminary condition: The Muting cycle can
only start if S1 and S2 are 0 (FALSE) and
the inputs are 1 (TRUE) (barrier free).
Parameters
Timeout (sec)
: Sets the time, between 10 secs and unlimited, within which the Muting cycle must
end. If the cycle is not complete at the end of this time, Muting is immediately discontinued.
Enable
: If selected it enables the possibility of enabling or not enabling the Muting function.
Otherwise the Muting function is always enabled.
There are two Enable modes: Enable/Disable and Enable Only. If Enable/Disable is
selected the Muting cycle cannot start if Enable is fixed at 1 (TRUE) or 0 (FALSE) but is
only activated with a rising edge. To disable muting, set Enable to 0 (FALSE). In this mode
the falling edge disables Muting regardless of the condition. If only Enable is selected
Muting cannot be disabled but Enable must be set to 0 (FALSE) in order to enable a new
rising edge for the next Muting cycle
.
Sensor time:
A difference of between 2 and 5 seconds can be set for activating the
sensors
.