74
MEDEA Programming Manual
5.11.2
SIAIP Advance Parameters
The
SIAIP
button located at the bottom of the telephone numbers table opens the section for setting the
parameters for SIAIP communications.
Figure 66 - SIAIP parameters
The following parameters will need to be programmed:
•
Protocol
: This is the data transmission protocol, which can be chosen between UDP and TCP.
•
Prefix
: This is a code provided by the security company and concerns the SIAIP receiver.
•
Receiver
: This is a code provided by the security company and concerns the SIAIP receiver.
•
Supervision
: Supervision is a DC-09 message that is sent periodically to the receiver at an interval
of time equal to that set to check reachability. If the security company does not respond, the control
panel classifies it as a system failure. If
Disabled
is selected, no check is performed. IMPORTANT!
To ensure compliance with EN 50136-2, supervision must be enabled if SP6 for a time not exceeding
20 seconds, if DP2 for a time not exceeding 30 minutes.
•
Retry Timeout (sec):
This is the delay, in seconds, of the retransmission of an event, against the
failure of the first sending. This parameter must be requested from the organisation to which it is sent.
5.11.3
Sending Message in Contact-ID Format
Figure 67
– Contact-ID parameters