52
MEDEA Programming Manual
5 -
PROGRAMMING
The submenus of the programming menu can be used to program the system and customise it according
to the needs of the system and the level of security that you want to obtain in accordance with the
customers' needs while respecting the simplicity of use.
5.1
Sectors
This can be used to configure the system sectors.
It is accessed through the
PROGRAMMING
→ Sectors
menu.
Figure 45 - Sectors
A list of all sectors of the system is displayed in table form.
The following information is provided for each sector:
•
NUMBER
: This is the number of the sector. The table lists all the sectors that can be managed by the
control panel.
•
ENABLED
: This indicates whether the sector is enabled or not. Sector 1 is always present (a system
must have at least one sector).
•
DESCRIPTION
: This is the alphanumeric label used to identify the sector more easily. With the
Generate audio function (
see paragraph 5.12 Audio
) the text entered is converted into an audio file
for use in voice messages. The description can be up to 32 characters long, chosen from alphabetical
characters, including accented characters, numbers and space; no other characters, such as special
characters or symbols, can be used.
•
ACTIVATION MODE
: This indicates how the sector must behave if, at the insertion of the intrusion
detection system, one or more associated intrusion inputs are open (intrusion alarm condition). The
possible options are:
o
Standard
: The sector is armed and an alarm is generated if any assigned inputs are open when
the sector is armed. Not compliant with EN 50131.
o
Auto-inhibit
: The intrusion inputs assigned to the sector which can be isolated and are open
when the sector is armed will be automatically isolated (no more than 70% of the inputs assigned
to the sector will be isolated; any inputs in excess will remain open and generate an alarm). The
isolated inputs will automatically end insulation if they are closed again. Not compliant with
EN 50131.
o
Activation-lock
: A sector programmed in this way cannot be armed if any assigned inputs are
open. Complies with EN 50131 Grade 2 and Grade 3.