60
MEDEA Programming Manual
Pulsed does not compromise conforming with EN 50131 as long as:
▪
It is activated by a timed scheduler output activation command.
The output no longer conforms with EN 50131 if:
▪
It is activated via app.
▪
It is triggered by a scenario.
o
Blink
: When active, it continuously switches from the ON to the OFF state, and vice versa, with
the times set in the
Blink ON
and
Blink OFF
parameters.
o
•
IDLE STATE
: This indicates the voltage present at the output terminal when it is at stand-by. The
possible configurations are:
o
Positive absent
: The terminal has potential 0 V.
o
Positive present
: The terminal has +12 V potential.
•
ACTIVATION DELAY
: This shows the delay, in seconds, with which the output is armed after having
received the arm command. Parameter available only for
Stabile
and
Blink
types.
•
ACTIVATION TIME
: This shows the delay, in seconds, with which the output is disarmed after having
received the disarm command. Parameter available only for
Stabile
and
Blink
types.
•
EVENTS HISTORY
: If the parameter is activated, the activation of the output is recorded in the Event
History.
•
REMOTE ACTIVATION BY APP
: This enables the output to be controlled remotely via app.
•
FOLLOWS OUTPUT
: This shows any other output whose activation activates the output being
configured.
•
OUTPUT GROUPS
: This indicates the groups to which the output is associated.
•
CATEGORY
: This defines which type of icon is displayed on the app for the output. This is used to
graphically define the type of output.
Double-click on the output line to open a pop-up window.
Figure 50 - Output customisation
In the pop-up window you can:
•
Change the
Logic ID
of the output. The drop-down menu shows only the logical identifiers that are still
available.
•
Enter the identification label of the output in
Description
. The text entered in
Description
is also used
to generate the voice messages as indicated by the symbol
. Use only alphabetic characters,
including accented characters, numbers, and spaces.
•
Define the output type (Type).
•
Determine the output terminal voltage when the output is in stand-by mode
(Idle State
).
•
Determine the delay time at which the output is activated (
Activation Delay
).