KOMET 200 - 600
10.3.1.8
Sequence P8: Warning prior to opening and closing
When sequence
P8
is activated by
button LERN
, the present value for
warning time (opening and closing) is displayed. With the
button BT
the value
can be selected (see table).Return to the learning sequence using
button
LERN
. The warning light is only active, when a gate wing is moving and during
warning prior to opening and closing.
Display
Warning time before
opening
Warning time before
closing
oo
No warning time
No warning time
o4
No warning time
4 seconds warning time
4o
4 seconds warning time
No warning time
44
4 seconds warning time
4 seconds warning time
Table 19
10.3.1.9
Sequence P9: Photo-cell function
When sequence P9 is activated by button LERN, the present selection for the
photo-cell function is displayed. With the button BT the value can be selected
(see table). Return to the learning sequence using button LERN.
Drawing 13
Function Photocell Gate
not
moving
Gate opens
Gate closes
l1
LSI Remains
not
moving
Stops when
interrupted,
opens when
free again
Stops when
interrupted,
opens when
free again
LSA Remains
not
moving
Stops when
interrupted,
opens when
free again
Stops when
interrupted,
opens when
free again
34