KOMET 200 - 600
Drawing 9
4. Fit the gate opener with the joint bolts into the mounting supports P and T
at gatepost and gate. Release the opener as described under 9. page 22
Now open and close the gate manually. Check if the gate can be moved
the complete distance between the end positions easily. Remove the gate
opener. Complete the final connection of the mounting supports P and T.
Grease the drill hole of the mounting support P slightly. Fit the gate opener
to the gate again. Tighten the screw at the gatepost, but not too tight.
Secure the fixing nut using the stop nut. Connect the joint bolt (gate) to the
mounting support T using the Screw.
5. All electrical connections should be according to the description for the MO
36control box 10 - Controller MO 36.
6. Now close the gate and engage the gate opener. Continue with 10.3 -
Programming MO36.).
7. Install now the periphery equipment like key switches, photo-cells etc. and
lay the electrical cabling according to the installation example on page 13.
Make sure that the cable cannot be tensed or damaged by the gate or the
moving gate opener.
8.4
Adjusting of the internal stops (KOMET 200 and 280)
If external stops are installed, make sure that the gate wing pushes
against the external stop with slight force only.
1. Disengage the emergency release as described under 9 - Emergency
release .
2. Move the gate wing/s to an opening angle of approx. 45°.
3. Reengage the emergency release.
4. Loosen the screw at the mounting support T.
5. Lift the narrow end of the gate opener out of the mounting support T.
6. Three counter sunk screws at the end of the arm and another three
between the aluminium arm and the push rod can now be seen from below
(these are the internal stops). Loosen these six screws. Move the internal
stops closer to the driver (joint bolt) using the socket wrench. Tighten the
screws slightly, so that the internal stops cannot shift accidentally on their
own.
19