KOMET 200 - 600
Table 21
10.3.1.11
Sequence PB: Lockage function for the photo-cells
Drawing 15
When using photo-cells in connection with the automatic closure for both
wings, a lockage function is possible. To activate this function use the learning
sequence.
The lockage function is only activated when the gate is opened.
When the gate reaches the end position OPEN, the lockage function is
initialised. This means: when a vehicle passes through the gate from the
outside, a signal from LSA (photo-cell outside) blocks the automatic
closure function. Only the signal from LSI (photo-cell inside) removes the
blocking and starts the stay-open time.
When a vehicle passes through the gate from the inside, a signal from LSI
blocks the automatic closure function. Only the signal from LSA removes
the blocking and starts the stay-open time.
When sequence
PB
is activated by
button LERN
, the present selection is
displayed. With the
button BT
the value can be selected (see table).Return to
the learning sequence using
button LERN
.
Display Corresponds
to:
xf
Lockage function is deactivated.
xn
Lockage function is activated (only working when automatic
closure is selected.) When the photo-cell is interrupted,
closing of the gate wing / wings is only possible, when the
vehicle / person has passed both (LSA and LSI) photo-cells.
Table 22
10.3.1.12
Sequence PC: Pressure relief of electromechanical bolt
When sequence PC is activated by button LERN, the present selection is
displayed. With the button BT the value can be selected (see table). Return to
the learning sequence using button LERN.
37