KOMET 200 - 600
10.9
Parameter and Original settings
Constant, not changeable values
Parameter
Original
settings
Time-lag before reactivating motor
500ms
Reversing for a short distance on obstacle
500ms
Time-lag before reversing
200ms
Max. running time limit
500s
Running time reserve during regular mode
10s
Warning time prior to emergency mode
10s
Table 29
Changeable values
Parameter
Selection
range
Original
settings
Running distance
Max. 32.000
Impulse
3.000
Impulse
Force
1 - 99
30
Speed
1 / 8
8
Time lag during opening
0s - 9s
2s
Time lag during closing
0s - 9s
5s
Stay-open time for both wings
1s - 299s /
OFF
OFF
Stay-open-time for pedestrian wing
1s - 299s /
OFF
OFF
Wind blast suppression
0s - 9s
0s
Warning prior to opening
0s / 4s
0s
Warning prior to closing
0s / 4s
0s
Pressure relief of electromagnetic bolt
0s / 1s / 2s /
90s
0s
Multi-functional relay
Push button
mode /
Togglemode
/ Light pulse
/ 3-minute
light
Push
button
LS lockage function
ON / OFF
OFF
Photo-cell function
L1 / L2 / L3
L1
Number of wings
1 / 2
1
Photo-cell testing
ON / OFF
OFF
44