background image

Owner’s Manual

 

Please read this manual and the enclosed safety materials carefully!

 

Fasten the manual near the garage door after installation.

   

The door WILL NOT CLOSE unless the Protector System

®

 is connected and properly 

aligned.

 

Periodic checks of the opener are required to ensure safe operation.

 

The model number label is located on the front panel of your opener.

 

DO NOT exceed 8 complete cycles of door operation per hour.

The Chamberlain Group, Inc.

845 Larch Avenue

Elmhurst, Illinois 60126-1196

www.liftmaster.com

COMMERCIAL DOOR OPENER

Model ATS 2113X 1/2 HP

For Residential And Light Duty Commercial Use
Install on Sectional Doors Only

H

I
G

H

L
O
W

N O R

M

A

L

H

I
G

H

L
O
W

N O R

M

A

L

UP

FORCE

DOWN
FORCE

®

Summary of Contents for ATS

Page 1: ...r are required to ensure safe operation The model number label is located on the front panel of your opener DO NOT exceed 8 complete cycles of door operation per hour The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 1196 www liftmaster com COMMERCIAL DOOR OPENER Model ATS 2113X 1 2 HP For Residential And Light Duty Commercial Use Install on Sectional Doors Only H I G H L O W NO R...

Page 2: ... 25 Care of your garage door opener 26 Having a problem 27 28 Programming 29 31 3 Button remote controls Optional 29 To add or change a Keyless Entry PIN Optional 30 Multi Function door control Optional 31 Repair Parts 32 33 Rail assembly parts 32 Installation parts 32 Motor unit assembly parts 33 Accessories 34 Notes 35 Repair Parts and Service 36 Warranty 36 TABLE OF CONTENTS When you see these ...

Page 3: ...ired NEVER try to loosen move or adjust garage door door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement This product is for use on sectional garage doors ONLY SERIOUS INJURY could result from the use of this product on on...

Page 4: ...ersal system may NOT work properly The floor or the garage door MUST be repaired to eliminate the gap Horizontal and vertical reinforcement is needed for lightweight garage doors fiberglass steel aluminum door with glass panels etc See page 19 for details Header Wall Wall Mounted Door Control Safety Reversing Sensor Torsion Spring OR Vertical Centerline of Garage Door Extension Spring Access Door Ra...

Page 5: ...fety Labels and Literature The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Rail Trolley Chain Pulley Bracket C Wrap 2 HARDWARE INVENTORY Assembly Hardware Installation Hardware Hardware for Safety Reversing Sensor Washered Bolt 5 16 18x1 2 2 Hex Screw 5 16 18x7 8 4 Lag Screw 1 4 x1 1 2 4 Mounted in Opener Nut 5...

Page 6: ...y the bolts previously removed from opener Tighten both bolts securely through the rail into the opener as shown Position the rail support bracket on the opener Attach the bracket to the rail with 1 4 20x5 8 hex bolts and lock washers DO NOT overtighten Attach the bracket to the opener by inserting a 5 16 18x1 2 washered bolt through a hole in each side flange and a matching hole in the bracket Com...

Page 7: ... WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener ONLY on properly balanced and lubricated garage door An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH 3 ALL repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener 4 Disable A...

Page 8: ...ersecting horizontal line on the header wall 2 5 cm above the high point This height will provide travel clearance for the top edge of the door Proceed to Installation Step 2 page 9 To prevent possible SERIOUS INJURY or DEATH Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling otherwise garage door might NOT reverse when required DO NOT install header bracket ov...

Page 9: ... the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing toward the wall The bracket can be mounted flush against the ceiling when clearance is minimal Mark the side holes Drill 3 16 pilot holes and fasten bracket securely to a structural support with the hardware provided HARDWARE SHOWN ACTUAL SIZE Header Bracket 2x4 Structural Support Vertical Centerline of Garage Doo...

Page 10: ...nto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 laid flat on the top section beneath the rail If the top section or panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect inner and outer sections Slide the outer trolley toward the motor unit The trolley can remain disconnected unt...

Page 11: ... 8 hex bolts lock washers and nuts 6 Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket Figure 1 Figure 2 To avoid possible SERIOUS INJURY from a falling garage door opener fasten it SECURELY to structural supports of the ...

Page 12: ...manently attach the entrapment warning label to the wall near the door control and the manual release safety reverse test in a prominent location on the inside of the garage door NOTE DO NOT connect the power and operate the opener at this time The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned See Saf...

Page 13: ...oorway is clear of persons and obstructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall To prevent possible OVERHEATING of the endpanel or light socket DO NOT use short neck or specialty light bulbs DO NOT use halogen bulbs Use ONLY incandescent INSTALLATION STEP 8 Attach the Emergency Release Rope and Handle Thread one end of the rope through the hole i...

Page 14: ...d Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the cover To avoid installation difficulties do not run the opener at this time To prevent possible SERIOUS INJURY or DEATH from electrocution or fire Be sure power is NOT connected to the opene...

Page 15: ...ectly into the receiving eye lens If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as the wall framing If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary The invisible light beam path must be unobstructed No part of the garage door or door t...

Page 16: ...s to the same distance out from mounting surface Make sure all door hardware obstructions are cleared Tighten the nuts securely Garage Door Track Installation Discard slotted bracket Drill 3 8 holes in each track and fasten securely with hardware as shown in Figure 3 HARDWARE SHOWN ACTUAL SIZE Screw 10 32x3 8 Carriage Bolt 1 4 20x1 2 Lag Screw 1 4 x1 1 2 Lock Nut 1 4 20 Lock Nut 10x32 Staples Figu...

Page 17: ...ensors follow the instructions below Cut the end of the safety reversing sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 8 Separate the safety reversing sensor wires and strip 1 4 6 mm of insulation from each end Choose two of the pre installed wires and strip 1 4 6 mm of insulation from each end Make sure that you choose the same color pre instal...

Page 18: ...e light beam path is not obstructed alignment is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sender s beam When the green indicator light glows steadily tighten the wing nut TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1 If the sending eye indicator light does not ...

Page 19: ... the face of the door within the following limits A The top edge of the bracket 2 4 5 10 cm below the top edge of the door B The top edge of the bracket directly below any structural support across the top of the door Mark and drill 5 16 left and right fastening holes Secure the bracket as shown in Figure 1 if there is vertical reinforcement If your installation doesn t require vertical reinforcem...

Page 20: ...idity Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up and join with bolts lock washers and nuts Proceed to Adjustment Step 1 page 21 Trolley will re engage automatically when opener i...

Page 21: ... force as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the DOWN limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close completely and the trolley bumps into the pulley bracket page 4 try lengthening the door arm page 20 and decreasing the down limit If the opener reverses in fully closed position Decrease...

Page 22: ...N close force by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the door 2 Test the UP open force Grasp the door bottom when the door is about halfway through UP open travel The door should stop If the door is hard t...

Page 23: ...tector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close the door The door will not move more than an inch 2 5 cm and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misali...

Page 24: ... 8 complete cycles of door operation per hour in commercial applications OPERATION IMPORTANT INSTALLATION INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH WARNING WARNING 1 READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS 2 ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with garage door control push buttons or remote controls 3 ONLY activate gar...

Page 25: ...ructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall LOCKOUT POSITION Trolley Release Arm Emergency Release Handle Down and Back MANUAL DISCONNECT POSITION Trolley Release Arm Emergency Release Handle Pull Down The door should be fully closed if possible Pull down on the emergency release handle and lift the door manually To reconnect the door to the ope...

Page 26: ... door opener rail Reapply a small layer of white lithium grease to the rail FORCE CONTROLS LIMIT CONTROLS NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFIC...

Page 27: ...l garage siding 5 Opener noise is disturbing in living quarters of home If operational noise is a problem because of proximity of the opener to the living quarters the Vibration Isolator Kit 89LM can be installed This kit was designed to minimize vibration to the house and is easy to install 6 The garage door opens and closes by itself Be sure that all remote control push buttons are off Remove th...

Page 28: ...springs may be broken Close the door and use the emergency release handle to disconnect the trolley Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not disconnect the opener and call a trained door systems technician Do not increase the force to operate the opener 15 The opener motor hums briefly the...

Page 29: ...n on the door control 4 After the opener lights flash release all buttons Test by pressing the remote push button The opener lights should turn on or off but the door should not move To Erase All Codes From Motor Unit Memory To deactivate any unwanted remote first erase all codes Press and the hold learn button on motor unit until the learn indicator light goes out approximately 6 seconds All previo...

Page 30: ... move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses this temporary PIN expires and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then pre...

Page 31: ...on page 15 To prevent possible SERIOUS INJURY or DEATH from electrocution Be sure power is NOT connected BEFORE installing door control Connect ONLY to 24 VOLT low voltage wires To prevent possible SERIOUS INJURY or DEATH from a closing garage door Install door control within sight of garage door out of reach of children at a minimum height of 5 feet 1 5 m and away from ALL moving parts of door NE...

Page 32: ...red 3 41A2828 Emergency release rope handle assembly 4 12B374 Door bracket 5 12B380 Door bracket plate 6 41A4353 Header bracket with clevis pin fastener 7 41A4373A Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire attached 8 178B35 Curved door arm section 9 12B483 C Wrap bracket 10 178B34 Straight door arm section 178B73 Straight door arm section 14 Foot 4 27 m door 11 ...

Page 33: ...r kit with grease Roll pins 2 5 143D100 1 Front end panel 6 175B88 Light socket 7 30B532 Capacitor 8 12A461 Capacitor bracket 9 41A3150 Terminal block with screws KEY PART NO NO DESCRIPTION 10 41D4509 Replacement motor bracket assembly Complete with Motor worm bracket bearing assembly 11 41A4593 5 Cover 12 81C253 Helical gear retainer with grease 13 41A5640 Limit switch assembly 14 41C4398A RPM se...

Page 34: ... for visitors or service persons This temporary password can be limited to a programmable number of hours or entries 78LM 12 Foot 3 66 m Complete Rail To allow a 12 foot 3 66 m door to open fully CD1012 14 Foot 4 27 m Complete Rail To allow a 14 foot 4 27 m door to open fully CD1014 Light Lens Cover Attractive lens cover protects light bulbs and diffuses light to every corner of your garage 108D36...

Page 35: ...35 NOTES ...

Page 36: ...onfirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller s sole option ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURP...

Page 37: ... ouvre porte de garage le vérifier et le régler périodiquement Vous trouverez le numéro de modèle sur un décalque situé sur le couvercle de l opérateur NE PAS faire fonctionner la porte plus de 8 fois par heure The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 1196 www liftmaster com OUVRE PORTE COMMERCIAL Modéle ATS 2113X 1 2 HP Pour usage résidentiel et commercial de petit rende...

Page 38: ... garage 26 Défauts de fonctionnement 27 28 Programmation 29 31 Télécommandes à trois canaux Facultatif 29 Panneau de commande de porte multifonction Facultatif 30 Pour ajouter ou modifier un NIP d entrée sans clé Facultatif 31 Pièces de réparation 32 33 Pièces d assemblage du rail 32 Pièces pour la pose 32 Pièces d assemblage du moteur 33 Accessoires 34 Remarques 35 Pièces de réparation et service...

Page 39: ...ies supports de porte ou leurs ferrures de montage lesquels sont TOUS sous une tension EXTRÊME Désactiver TOUTES les serrures et retirer TOUTES les cordes raccordées à la porte de garage AVANT de poser et d utiliser l ouvre porte de garage afin d éviter un emmêlement Ce produit est conçu pour l utilisation avec une porte de garage articulée SEULEMENT Son utilisation avec une porte de garage monopiè...

Page 40: ...le plancher ou la porte de garage pour éliminer l espace AVERTISSEMENT Il faudra poser des renforts horizontaux et verticaux dans le cas d une porte de garage légère en fibre de verre en acier en aluminium en panneaux de verre etc Se reporter à la page 19 pour plus de détails Linteau Commande de porte murale Détecteur inverseur de sécurité Ressort de torsion OU Ligne du centre vertical de la porte ...

Page 41: ...a pose Fixations pour détecteur inverseur de sécurité Vis à rondelle frein de Vis à tête hexagonale de Tire fond de 1 4 po x 1 1 2 po 4 5 16 de po 18 x 1 2 po 2 5 16 de po 18 x 7 8 de po 4 Boulon à tête bombée et à collet carré de montées dans l ouvre porte Écrou de 5 16 de po 18 4 1 4 de po 20 x 1 2 po 4 Vis à tête hexagonale de Rondelle frein de 5 16 de po 4 Écrou indesserrable de 1 4 de po 20 4...

Page 42: ...ement à travers le rail et dans le moteur comme illustré Positionner le support du rail sur l ouvre porte Attachez le support au rail avec les vis à tête hexagonale de 1 4 po 20 x 5 8 po et leurs rondelles freins NE PAS trop serrer Attachez le support à l ouvre porte en insérant une vis à rondelle de 5 16 po 18 x 1 2 po à travers un orifice dans chaque bride latérale et l orifice correspondant du su...

Page 43: ...r une porte de garage bien équilibrée et lubrifiée Une porte mal équilibrée peut NE PAS remonter au besoin et pourrait provoquer des BLESSURES GRAVES ou LA MORT 3 TOUTES les réparations aux câbles ensembles de ressort et autres ferrures de montage DOIVENT être confiées à un technicien formé en systèmes de porte AVANT de poser l ouvre porte 4 Désactiver TOUTES les serrures et retirer TOUTES les corde...

Page 44: ...dessus du point le plus haut Cette hauteur permettra d obtenir un dégagement suffisant pour le passage de la partie supérieure de la porte Passer à la 2e Pose opération page 9 Pour prévenir d éventuelles BLESSURES GRAVES ou la MORT Le support de linteau DOIT être fixé DE MANIÈRE RIGIDE à la solive sur le linteau ou le plafond sinon la porte de garage pourrait NE PAS remonter au besoin NE PAS poser l...

Page 45: ...ntée vers le mur Le support peut être encastré dans le plafond si le dégagement n est pas suffisant Marquer les trous latéraux Percer des avant trous de 3 16 po et fixer fermement le support sur une solive du plafond à l aide des fixations fournies Support de tête Support structural de 2 x 4 Ligne du centre vertical de la porte de garage Trous de montage mural optionnels Tire fond de 5 16 po 9 x 1 5 ...

Page 46: ...escabeau Si l escabeau n est pas assez haut demander de l aide Ouvrir complètement la porte et mettre un 2 x 4 à plat sur sa partie supérieure sous le rail Si le panneau ou la section du dessus vient en contact avec le chariot lorsqu on lève la porte tirer sur la biellette de dégagement du chariot pour dégager le chariot intérieur du chariot extérieur Faire glisser le chariot extérieur vers le mot...

Page 47: ... rail est centré au dessus de la porte ou dans le prolongement du support de linteau si le support n est pas centré au dessus de la porte 7 Retirer le 2 x 4 Faire fonctionner la porte manuellement Si la porte frappe le rail lever le support de linteau Figure 1 Figure 2 Pour éviter d éventuelles BLESSURES GRAVES par suite de la chute d un ouvre porte de garage fixer l ouvre porte SOLIDEMENT aux soli...

Page 48: ...e de porte et l étiquette d essai d inversion de sécurité ouverture manuelle bien en vue à l intérieur de la porte de garage REMARQUE NE PAS brancher et faire fonctionner l ouvre porte pour le moment Le chariot se déplacera jusqu à la position complètement ouverte mais ne reviendra pas à la position fermée avant que le faisceau détecteur soit branché et correctement aligné Voir les instructions au...

Page 49: ...agée absence de personnes et d obstacle Ne JAMAIS utiliser la poignée pour ouvrir ou fermer la porte Il y a risque de chute si le nœud de la corde se défait Pour éviter toute SURCHAUFFE éventuelle du panneau d éclairage NE PAS utiliser d ampoules à col court ou de forme spéciale NE PAS utiliser d ampoules halogène Utiliser UNIQUEMENT des ampoules incandescentes POSE 8e OPÉRATION Pose de la corde e...

Page 50: ... fil noir courant secteur sur la vis de la borne en laiton le fil blanc neutre sur la vis de la borne en argent puis le fil de terre sur la vis verte de terre L ouvre porte doit obligatoirement être mis à la terre Reposer le couvercle Pour éviter les difficultés pendant la pose ne pas faire fonctionner l ouvre porte pour le moment Pour prévenir d éventuelles BLESSURES GRAVES ou la MORT par suite d éle...

Page 51: ...orts doivent être fixés fermement à une surface solide telle que la charpente du mur Si la pose se fait dans une construction en maçonnerie ajouter un morceau de bois à chaque endroit pour éviter de percer des trous supplémentaires dans la maçonnerie si un repositionnement est nécessaire Il ne doit y avoir aucun obstacle sur le parcours du faisceau de lumière invisible Aucune partie de la porte de ...

Page 52: ...uche et droit à la même distanc de la surface de fixation S assure qu aucune piéce de fixation de la porte ne gêne le faisceau lumineux Serrer fermement les écrous Installation sur coulisse de porte Eliminer les supports de fixation avec fente Percer des trous de 3 8 de pouce dans chaque coulisse et attacher solidement avec les fixations illustrée à la Figure 3 GRANDEUR RÉELLE DES FIXATIONS Vis N 10 3...

Page 53: ...age appliquez les instructions ci dessous Coupez l extrémité du câble du capteur de l inverseur de sécurité en vous assurant qu il reste suffisamment de longueur pour atteindre les câbles préinstallés depuis le mur Figure 8 Séparez les câbles du capteur de l inverseur de sécurité et dénudez sur chaque extrémité 1 4 po 6 mm de l isolant Choisissez deux des câbles préinstallés et dénudez sur chaque e...

Page 54: ...lumineux invisible n est pas obstruée aligner les deux détecteurs Desserrer l écrou de la cellule émettrice et ajuster de façon à ce qu elle vise directement la cellule réceptrice Serrer l écrou Desserrer l écrou de la cellule réceptrice et régler le détecteur jusqu à ce qu il reçoive le faisceau de la cellule émettrice Lorsque le témoin vert reste allumé serrer l écrou DÉPANNAGE DES DÉTECTEURS IN...

Page 55: ...spectant les limites suivantes A Le bord supérieur du support doit être entre 2 et 4 pouces 5 et 10 cm plus bas que le bord supérieur de la porte B Le bord supérieur du support doit être placé directement sous le support structurel placé en haut de la porte Repérer et percer les trous de fixation gauche et droit de 5 16 de pouce Faire tenir le support comme il est illustré à la Figure 1 si un renfo...

Page 56: ...la biellette droite et couper 6 po 15 cm du bout Refixer la biellette droite sur le chariot en orientant la partie coupée vers le bas comme illustré Rapprocher les biellettes Aligner deux paires de trous et raccorder les deux biellettes avec les boulons les rondellesde blocage et les écrous Passer à la section Réglages 1re opération page 21 Le chariot se réenclenchera automatiquement lorsque l ouvr...

Page 57: ...pas complètement Augmenter la course de fermeture en tournant la vis de réglage DOWN dans le sens antihoraire Un tour complet de la vis correspond à 2 po de course Si la porte ne se ferme toujours pas complètement et que le chariot heurte le support de la poulie page 4 essayer de rallonger le bras de la porte page 20 et de diminuer la course de fermeture Si l ouvre porte fait remonter la porte lor...

Page 58: ...églages jusqu à ce que la porte fasse un cycle de fermeture complet Après chaque réglage Faire un cycle complet à l ouvre porte Ne pas augmenter la force au delà du niveau nécessaire pour fermer la porte 2 Vérification de la force d ouverture UP Pendant que la porte est environ à mi chemin de sa course d ouverture essayer de l arrêter à la main La porte doit s arrêter S il est difficile de retenir l...

Page 59: ... le bouton poussoir de la télécommande pour ouvrir la porte Mettre la boîte en carton de l ouvre porte dans la course de la porte Appuyer sur le bouton poussoir de la télécommande pour fermer la porte La porte ne se déplacera pas de plus d un pouce et les lumières de l ouvre porte clignoteront La porte de garage ne se fermera pas à l aide d une télécommande si le témoin lumineux d un des deux déte...

Page 60: ...ra la porte de garage ouverte Ne dépassez pas 8 cycles complets d operation de la porte par heure en usage commercial IMPORTANTES CONSIGNES DE SÉCURITÉ 1 LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS 2 TOUJOURS garder les télécommandes hors de la portée des enfants Ne JAMAIS laisser les enfants faire fonctionner les télécommandes ou les boutons poussoirs de la commande de porte ou jouer a...

Page 61: ...mer la porte Il y a risque de chute si le nœud de la corde se défait AVERTISSEMENT Dans la mesure du possible la porte doit être complètement fermée Tirer la poignée de déclenchement d urgence et lever la porte manuellement Pour rattacher la porte à l ouvre porte appuyer sur la barre poussoir de la commande de porte La fonction de verrouillage empêche le chariot de se réenclencher automatiquement ...

Page 62: ...se sur le rail de l ouvre porte de garage Appliquez de nouveau une fine couche de graisse blanche au lithium sur le rail COMMANDES DE FORCE COMMANDES DE COURSE AVIS Les règles de la FCC ou d Industrie Canada IC ou les deux interdisent tout ajustement ou toute modification de ce récepteur et ou de cet émetteur sauf pour modifier le code ou pour remplacer la pile IL N EXISTE AUCUNE AUTRE PIÈCE SUSCEP...

Page 63: ...nement plus court à cause d une porte métallique d isolation à revers d aluminium ou d un garage avec revêtement métallique 5 L ouvre porte se fait fortement entendre dans la résidence quand il fonctionne Un nécessaire d insonorisation 89LM peut être posé Cet équipement est conçu pour minimiser les vibrations à la maison et est facile à installer 6 La porte s ouvre et se ferme toute seule S assure...

Page 64: ... ressorts sont cassés Fermer la porte et utiliser la poignée de déclenchement d urgence pour détacher le chariot Ouvrir et fermer la porte à la main Une porte bien équilibrée restera à sa position d arrêt entièrement supportée par les ressorts le cas contraire détacher l ouvre porte et appeler un technicien formé en systèmes de porte Ne pas augmenter la force pour faire fonctionner la porte du gar...

Page 65: ... boutons Faire un essai en appuyant sur le bouton poussoir de la télécommande L éclairage de l ouvre porte doit s allumer ou s éteindre sans que la porte ne bouge Pour effacer tous les codes de la mémoire du moteur Pour inactiver toute télécommande non désirée effacer d abord tous les codes Enfoncer et tenir le bouton learn du moteur jusqu à ce que le témoin lumineux learn s éteigne environ 6 seco...

Page 66: ...temporaire Vous pouvez autoriser l accès aux visiteurs ou aux techniciens de service à l aide d un NIP temporaire à 4 chiffres Après un nombre programmé d heures ou un nombre programmé d utilisations ce NIP temporaire vient à expiration et n ouvre plus la porte On peut l utiliser pour fermer la porte une fois qu il a expiré Pour définir un NIP temporaire 1 Appuyer sur les quatre boutons corresponda...

Page 67: ...rant est coupé AVANT de poser la commande de porte Raccorder UNIQUEMENT à des fils basse tension 24 V Pour prévenir d éventuelles BLESSURES GRAVES ou la MORT par suite d une porte de garage qui se ferme Poser la commande de porte en vue de la porte de garage hors de la portée des enfants à une hauteur minimum de 5 pieds 1 5 m et à l écart de TOUTES les pièces mobiles de la porte Ne JAMAIS laisser d...

Page 68: ...ucteurs 3 41A2828 Poignée et corde pour fonctionnement d urgence 4 12B374 Support de porte 5 12B380 Plaque de support de porte 6 41A4353 Support de linteau avec axe de chape et fixation 7 41A4373A Nécessaire de capteur de sécurité yeux de réception et de transmission avec fil de sonnerie à deux conducteurs de 3 pi 0 9 m 8 178B35 Biellette courbée 9 12B483 Profilé 10 178B34 Biellette droite 178B73 Bie...

Page 69: ...cylindrique 2 5 143D100 1 Panneau d extrémité avec toutes les étiquettes 6 4A1344 Douille d ampoule 7 30B532 Condensateur 8 12A461 Support de condensateur 9 41A3150 Bornier avec vis N DE RÉF PIÈCE DÉSIGNATION 10 41D4509 Ensemble de rechange moteur et support de montage Comprend Moteur vis sans fin support roulement capteur de régime 11 41A4593 5 Couvercle 12 81C253 Pil et flasque avec graisse 13 41A...

Page 70: ... les préposés au service Ce code programmable peut être limité à un nombre programmable d heures ou d entrées 78LM Rail complet de 12 pieds 3 66 m Pour permettre à une porte de 12 pieds 3 66 m de s ouvrir complètement CD1012 Rail complet de 14 pieds 4 27 m Pour permettre à une porte de 14 pieds 4 27 m de s ouvrir complètement CD1014 Couvercle de lentille Le couvercle attrayant de lentille protège ...

Page 71: ...35 REMARQUES ...

Page 72: ...t couverts par la présente garantie limitée ils seront réparés ou remplacés à la seule discrétion du Vendeur sans frais pour l acheteur puis retournés en port payé Les pièces défectueuses seront réparées ou remplacées par de nouvelles pièces ou des pièces remises à neuf en usine à la seule discrétion du Vendeur TOUTES GARANTIES TACITES RELATIVES À CE PRODUIT DONT SANS TOUTEFOIS S Y LIMITER TOUTE G...

Reviews: