Site Wiring

TIP: 

Most technical calls received are due to installers using CAT5 or alarm cable 

to power the unit.

NEITHER

are rated to carry enough power! 

( 1.2amp peak )

Please use the following cable:

Up to 2 metres ( 6 feet )     

Use minimum 

0.5mm

2

( 18 gauge )

Up to 4 metres ( 12 feet )   

Use minimum 

0.75mm

( 16 gauge )

Up to 8 metres ( 24 feet )   

Use minimum 

1.0mm

2

( 14 gauge )

POWER CABLE

INGRESS PROTECTION

We recommend sealing all entry holes for prevention of insects that can 
cause issues with a risk of shorting out components.

To maintain the IP55 rating please follow the sealing instructions included. 
(also available online)

2

iGate Enclosure

(Install at height to allow the 

internal antenna to find signal.)

DC Power Cable

(1.0mm2 

– 8m MAX)

Note:

PSU not supplied. 

Can be purchased separately. 

24v DC 1.2A peak.

SIM Preparation

Ensure you read all instructions before 
continuing. 

The SIM cards provided need activated 
before use. 

Follow the instructions 

provided or visit our telecoms website for 
more details:

www.aesglobaltelecom.com

1

Ensure there is good 
4G signal on site. 4G 
units will fall back to 
3G service in some 
countries.

SITE SURVEY

This product requires a basic SMS SIM card. Ensure there is a data 
allowance to avoid any potential charges.

Do not use a data only SIM, as this will not work in the unit.

Set up on a bench in workshop 

BEFORE

going to site. 

Program the unit in the comfort 
of your work bench and call 
technical support should you 
have any questions.

Please read this entire manual before installing this 
product. A full comprehensive manual is available on 
our website for additional information. 

ENSURE THE POWER SUPPLY IS REGULATED & DOES NOT 

EXCEED 28V AC/DC.

101

101

8

.000

R1

24V 

DC IN

LIGHTNING PRONE AREAS MUST USE SURGE PROTECTION 

FOR POWER SUPPLY!

Relay Connections

Example

4

See overleaf for 

more PCB details

Turn Over

1

Power

3

24V DC IN

(Polarity Protected)

4G Antenna

- GSM Gate Opener

STILL HAVING TROUBLE? 

Find all of our support options such as Web Chat, 

Full Manuals, Customer Helpline and more on 

our website:

WWW.AESGLOBALUS.COM

iGate 1200

R

e

la

y

8

.000

R

V

T

R

V

T

R

V

T

R

V

T

R

el

ay

Driveway

 

Gates

Gate

 

Controller

Reviews: