Page 1: ...SMART SYSTEMS FOR ACCESS CONTROL AUTOMATIC GATE OPENER INSTALLATION MANUAL Model G452 For Double Gates Part 7001623 002 Rev 1...

Page 2: ...dock area or other locations not intended to service the gen eral public Restricted Access Vehicular Gate Opener Class IV A vehicular gate opener or system intended for use in a guarded industrial lo...

Page 3: ...ation and use of the Product The Zareba Automatic Gate Opener is for use on vehicular fence gates only The Product meets or exceeds the requirements of UL 325 the standard that regulates gate opener s...

Page 4: ...page 18 Power Connection Between Control Box and Gate Openers Actuators page 18 Push to Open Installation page 22 Brick Masonry or Rock Column Installation page 24 Control Box Setting Control Board Se...

Page 5: ...Gate Opener Your Zareba Automatic Gate Opener is designed for years of trouble free performance It will provide you with a comfortable safe hassle free way to access your property This Automatic Gate...

Page 6: ...stops Do not drive forward until the gate stops completely Protection Against Entrapment Important Study Figures 1 and 2 and keep safety fore most at all times Entrapment areas for a proper pull to o...

Page 7: ...eba Systems for replacements 7 Protection Against Entrapment The Zareba Automatic Gate Opener is designed to com ply with UL 325 the safety standard covering automatic gate opening systems UL 325 requ...

Page 8: ...s Call Zareba Systems at 1 800 272 9877 for information on compatible products for your application Important In all cases review the safety device manu facturer s instructions for information on inst...

Page 9: ...Items You May Need for Installation Low voltage wire This is needed to run from the transformer to the control box You ll need enough to cover the distance between the transformer power supply and the...

Page 10: ...7001221 001 3 8 Lock washer 22 7001227 001 Gate opener actuator with 10 power cable 1 7001618 001 Gate bracket 2 7001215 001 Post bracket 4 7001217 001 Post pivot bracket 2 7001218 001 Closed positio...

Page 11: ...11 Installed Automatic Gate Opener Transformer Gate opener actuator Control box Closed position stop plate Gate bracket Post bracket Gate opener actuator Buried power cable...

Page 12: ...5 inches Adjustable auto close timer OFF to 120 seconds and obstruction sensitivity Provisions made for digital keypads pull to open push to open buttons contact safety edge sensors and non contact p...

Page 13: ...applied If you are using gate posts small er than 6 diameter or square they should be 1 made of metal and 2 set in cement to ensure the stability of the post Gate Reinforcement Methods fig 11 IMPORTA...

Page 14: ...end of the gate openers actuators Secure the clevis pins using the clevis pin clips Figure 11 Method Two Method One Thin walled tube gate Gate bracket Wood or metal reinforcement not included Steel pi...

Page 15: ...mini mum 2 clearance exists between the gate and the gate opener actuator in both the gate open and gate closed positions To ensure the 2 clearance mini mum is maintained in the gate closed position...

Page 16: ...by taking off the C clamps Step 6 fig 16 Using a drill and a 3 8 bit drill holes through the gate post and the gate at the marked bolt hole locations NOTE When drilling holes into the gate post and t...

Page 17: ...tes use wood or lag screws For tube or chain gates use U bolts Step 9 fig 19 With the gate in the desired closed position loosely fasten the gate stop plate to the middle of the gate between the top a...

Page 18: ...e four clevis pins Insert one clevis pin through the gate opener actuator and the gate brack et Insert the other clevis pin through the gate opener actuator and the post mount bracket assembly Secure...

Page 19: ...Connect the Gate Openers Actuators to the Control Box CAUTION Ensure that the control box power switch is in the OFF position before connecting the control box Step 14 fig 25 Insert the first gate ope...

Page 20: ...e 28 Strain relief housings Gate opener cables Figure 27 Step 15 fig 26 Connect the color coded gate opener actuator wires to the terminal block located on the bottom of the con trol board marked Open...

Page 21: ...ansformer Caution The transformer must not be plugged in when connecting power Step 20 fig 30 Run the 16 gauge wire in a trench from the control box to the 110 VAC outlet The wire must be protected as...

Page 22: ...ough the center hole of the two post mount brackets and the push to open bracket Place a 3 8 washer a 3 8 lock washer and a 3 8 hex nut on the bottom of the 3 8 x 2 hex bolt and hand tighten Step 2 fi...

Page 23: ...by ensuring a 2 minimum clearance is maintained between the gate and the gate opener actuator in both the gate open and gate closed positions To ensure the minimum 2 clear ance is maintained in the g...

Page 24: ...sounds an alarm when an obstruction occurs twice in any given cycle The obstruction alarm cannot be disabled by turning this DIP switch to the OFF position DIP Switch 3 Automatic Close When this DIP...

Page 25: ...ore first gate 1 ON 2 OFF 3 OFF First gate begins to open two seconds before second gate Second gate begins to close four seconds before first gate 1 OFF 2 OFF Factory setting for single opener actuat...

Page 26: ...combination of the switches to either the open or closed position NOTE Do not set the switches to all open or all closed Step 3 Remove the control box cover by removing the four screws When the cover...

Page 27: ...hed by Gate Opener 2 Step 3 Set Dual Mode DIP switch 4 of the Dual Mode Settings to the ON position then press and hold the SET LIMIT button for two seconds fig 44 You will hear a single BEEP from the...

Page 28: ...stop position Figure 45 Step 6 Set Dual Mode DIP switch 4 to the OFF position and then press and hold the SET LIMIT button for two sec onds You will hear a single BEEP from the alarm buzzer and the S...

Page 29: ...t liable or responsi ble for non Zareba branded accessories For a list of all optional accessories see page 34 Figure 46 Charging the Battery Upon initial installation the battery may not be charged a...

Page 30: ...ect the gate opener actuator when the control box power switch is OFF and the gate is NOT moving Disconnecting the Opener fig 47 1 Turn control box power switch OFF 2 Remove clevis pin clip and clevis...

Page 31: ...s are on c Verify the wires connected to VAC SOLAR if appli cable OPENER 1 OPENER 2 if applicable CYCLE SAFETY EXIT SHADOW and RECEIVER terminals are not loose 6 If steps 1 5 did not solve the problem...

Page 32: ...le CYCLE SAFETY EXIT SHADOW and RECEIVER terminals are not loose 3 Verify the 15 amp fuse is not blown 4 If steps 1 3 do not reveal an existing problem please contact customer service When my gates cl...

Page 33: ...shipping carton include i a letter detailing the complaint ii a daytime phone number where you can be reached iii your name and address for any return iv your sales receipt proof of purchase and v th...

Page 34: ...ws for entry by authorized guests informed of your pre set code Entering the correct code causes the gate to open or close The access code is easily modified In Ground Vehicle Sensor GS1 The sensor is...

Page 35: ...tate Zip ________________________________________________________________________________________ Phone __________________ Email _______________________________________________________________ Accesso...