background image

Garage-door operator

VER-PLUS series

VER10DMS-VER13DMS

INSTALLATION MANUAL

EN English

FA01358-EN

Summary of Contents for VER-PLUS Series

Page 1: ...Garage door operator VER PLUS series VER10DMS VER13DMS INSTALLATION MANUAL EN English FA01358 EN ...

Page 2: ......

Page 3: ...wer than 2 5 from the ground or from any other access level fit any protections and signs to prevent hazardous situations Do not fit the operator upside down or onto elements that could yield to its weight If necessary add reinforcements to the fastening points Do not install unless door is level to the ground Suitably section off and demarcate the entire installation site to prevent unauthorized pe...

Page 4: ...ompletely cut off the power supply according to category III surcharge conditions The gear motor must be only powered by very low safety voltage which corresponds to what is stated in the markings on the gear motor Keep the section of this manual inside the technical folder along with the manuals of all the other devices used for your automation system Remember to hand over to the end users all th...

Page 5: ... which parts describe safety issues This symbol shows which parts to tell users about The measurements unless otherwise stated are in millimeters DESCRIPTION Automated operator featuring a control panel with encoder for sectional and overhead garage doors Intended use The VER10DMS VER13DMS operators are developed to drive overhead and sectional garage doors in private homes and apartment buildings...

Page 6: ...4 Control board 5 Operator configuration buttons 6 Standard drive arm for the VER10DMS 7 Standard drive arm for the VER13DMS 8 Door fastening brace 9 Guide fastening brace 10 Ceiling fastening brackets 11 Cable gland 12 Fastening screws 13 Cover fastening hinge 14 Courtesy light Only for sectional doors Dimensions Page 6 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be change...

Page 7: ...ht Sectional doors up to 2 20 m in height Belt drive 001V0685 Belt drive L 3 02 m Counter balanced overhead doors up to 2 4 m in height Counter balanced overhead doors up to 2 25 m in height Sectional doors up to 2 20 m in height 001V0686 Belt drive L 3 52 m Counter balanced overhead doors up to 2 75 m in height Sectional doors up to 2 70 m in height 001V0687 Chain guide L 3 02 in two pieces Count...

Page 8: ...ories 001 001V005 Extension for the following types of chain guides V0679 V0682 V0683 V0684 001 001V201 Transmission arm for partially retracting overhead garage doors 001 001V122 Transmission arm for sectional doors having a top rail to spring pole assembly distance comprised between 300 and 600 mm 001V121 Pull cord auto resetting release device to fit onto the door handle 801XC 0010 Emergency car...

Page 9: ... original instructions Standard installation 1 Operator 2 Guide 3 Release device 4 Transmission arm 5 Key switch selector 6 Photocells 7 Control device 8 Sensitive safety edge 9 Flashing light and antenna Page 9 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original instructions ...

Page 10: ...hat comply with EN 50267 2 1 CEI To connect the antenna use the RG58 we suggest up to 5 m For paired connection and CRP use a UTP CAT5 type cable up to 1 000 m long If cable lengths differ from those specified in the table establish the cable sections depending on the actual power draw of the connected devices and according to the provisions of regulation CEI EN 60204 1 For multiple sequential loa...

Page 11: ...part of the door is between 300 mm and 600 mm use the V122 transmission arm INSTALLATION Only skilled qualified staff must install this product The following illustrations are mere examples in that the space for fastening the operator and accessories varies depending on the installation area It is up to the fitter therefore to choose the most suitable solution Assembling the guide Page 11 Manual FA0...

Page 12: ...e hinge to the cover by using the supplied screws Fit the cover onto the operator For protracting partially retracting overhead doors use the V201 transmission arm optional accessory For protracting overhead doors keep the guide 20 mm from the opening high point Page 12 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original instructi...

Page 13: ...s and adapt them to the required height If necessary fit additional support rods Use suitable screws and dowels Fastening the guide shaft Fasten the guide shaft to the center of the door opening Use suitable bolts Raise the guide shaft and position it horizontally to measure the distance from the ceiling and then fasten it Page 13 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may...

Page 14: ... operator to the guide Fasten the operator to the guide shaft by using the supplied screws The operator can also be fitted laterally Turn the release tab counter clockwise Move the traction assembly towards the door and fasten the transmission arm using the supplied bolt Page 14 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original i...

Page 15: ...t and output contacts time adjustments and user management settings are set and viewed on the control board s display All connections are fuse protected Fuses ZL57 Line 630 mA T 230 V Motor 8 A F Accessories 2 A F Courtesy light Technology LEDs Power supply V 24 DC Plug E14 Consumption W 1 Perforate the cable gland run the cables through and fit the cable gland into its brace The number of cables d...

Page 16: ...rminals 13 Connector for the DPT01 programming card 14 Terminal board for transponder selector 15 CRP connection terminals 16 RSE card connector It excludes local connection with Came Key 17 Terminal board for control and safety devices 18 Terminal board for warning devices 19 Memory Roll card connector 20 RGP1 module terminal 21 Connector for the RIOCN8WS card 22 Power supply on warning LED 23 Li...

Page 17: ...nnection output for flashing or cycle light Contact rated for 24 V AC DC 25 W See function F18 Signaling devices Ref Description Ⓛ HD Analog Ground Ⓝ Neutral Accessories power supply output 24 V AC DC max 20 W 24 V AC DC control board power supply input 230 V AC 50 60 Hz Input voltage Green Red Encoder Factory wiring Green Brown White 24 V DC gearmotor Page 17 Manual FA01358 EN 07 2019 CAME S p A T...

Page 18: ...m control device NO contact Alternatively the functions programming lets you activate other controls See function F 7 STOP button NC contact Enables the door to stop and excludes the automatic closing To resume movement press the control button or use another control device See function F1 OPEN or PARTIAL OPENING function from control device NO contact See function F8 Command and control devices F...

Page 19: ... causes the door to invert its move ment until it is completely open C2 close back up during opening When the door is opening opening the contact causes the door to invert its movement until it is completely closed C3 partial stop Stop door if it is moving with consequent automatic closing if the automatic closing function is on C4 obstruction wait Stop door if it is moving which resumes movement ...

Page 20: ...s movement until it is completely closed r7 reopening during closing 8K2 resistive input When the door is closing opening the contact causes the door to invert its movement until it is completely open r8 reclosing during opening 8K2 resistive input When the door is opening also opening the contact will cause the door to invert its direction until it completely closes If unused contacts CX and CY s...

Page 21: ...LY and remove any batteries Plug the RIOCN8WS card into its corresponding connector on the control board Set up the function that you are going to associate to the wireless device F65 F66 F67 e F68 Configure the RIOED8WS RIOPH8WS and RIOLX8WS wireless devices Follow the instructions detailed in the installation and accessories manuals If the devices are not configured with the RIOCN8WS card the disp...

Page 22: ...PEN command The ENTER key is for entering menus confirming or memorizing set values The ESC button is for exiting menus deleting changes commanding a STOP when the motors are in motion Transmitter and data storage Before plugging in the card YOU MUST CUT OFF THE MAINS POWER SUPPLY and remove any batteries To enter change and delete user or to control the operator via the radio command fit the AF car...

Page 23: ...fety edges OFF Deactivated default C1 C2 C3 C4 C7 C8 r7 r8 The C3 setting appears only if F19 is active F 5 Safety test After every opening or closing command the board will check whether the photocells are working properly OFF Deactivated default 1 CX 2 CY 4 CX CY F 6 Maintained action The door opens and closes by keeping the button pressed Opening button on contact 2 3P and closing button on con...

Page 24: ...ing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds The automatic closing does not work if any of the safety devices trigger when an obstruction is detected or after a total stop or during a power outage OFF Deactivated default 1 1 second 180 180 seconds F20 Automatic closing time after partial opening The wait before the automatic closing sta...

Page 25: ...1 1 of the door travel 5 5 of the door travel default 60 60 of the door travel F42 Adjusting the closing slow down Percentage adjustment of the total door travel from the closing slow down starting point 1 1 of the door travel 15 15 of the door travel default 60 60 of the door travel F44 Adjusting the closing approach Adjusting as a percentage of the total door travel of the closing approach start...

Page 26: ...y appears if the RIOCN8WS card is plugged into the control board OFF Deactivated default P0 P7 P8 F67 Wireless input RIOPH8WS T1 RIOPH8WS wireless safety device associated to one of the following available functions P 1 reopening during closing P 2 reclosing during opening P 3 partial stop P 4 obstruction wait For programming see the instructions that come with the accessory This function only app...

Page 27: ...ry lifting of the window door A2 Motor test Test to verify the gear motor s proper direction of rotation see the MOTORS TEST paragraph OFF Deactivated ON Activated A3 Gate swing calibration Automatic calibration of the door travel see the CALIBRATION DOOR TRAVEL paragraph OFF Deactivated ON Activated A4 Resetting parameters Caution For restoring the default factory settings and deleting the gate t...

Page 28: ...umbers that are avai lable for other users max 250 users Caution Before entering users unplug any Memory Roll card Select U1 Press ENTER to confirm Select a command to associate to the user The commands are 1 step step open close 2 sequential open stop close stop 3 open 4 partial opening Press ENTER to confirm A number between 1 and 250 will blink for a few seconds This number will be assigned to th...

Page 29: ...erify whether the door opens Deleting a single user Select U2 Press ENTER to confirm Select the user number to delete Press ENTER to confirm The Clr wording will appear to confirm the deletion Motor test Select A2 Press ENTER for confirm Select ON to activate the test Press ENTER to confirm The following characters will appear while waiting for the command Page 29 Manual FA01358 EN 07 2019 CAME S p A T...

Page 30: ... Mechanical stop Place the opening mechanical stop against the sliding guide and fasten it Gate swing calibration N B before calibrating the travel check that the maneuvering area is free of any obstructions Important During the calibration all safety devices will be disabled except for the PARTIAL STOP one Select A3 Press ENTER to confirm Select 1 and press ENTER to confirm The door will close comp...

Page 31: ...5 Transmitter error E17 Wireless system error E18 The wireless system configuration is missing Obstruction detection when CLOSING The door inverts its travel direction and reopens After two consecutive inversions when closing the door stays open and the automatic closing is excluded After three consecutive detections when opening and or closing the door stops To reclose the door press a control but...

Page 32: ...the devices and the electric cables are in proper working conditions The operator opens but will not close The photocells are working Check that there are no obstructions in the range of operation of the photocells If the problem cannot be solved by following the fixes in the table or if any malfunctions anomalies noises vibrations or suspicious and unexpected behavior is experienced on the system...

Page 33: ...ste and simply separated from other waste for recycling Always make sure you comply with local laws before dismantling and disposing of the product DISPOSE OF RESPONSIBLY DISMANTLING AND DISPOSAL Our products are made of various materials Most of these aluminum plastic iron electrical cables are classified as solid household waste They can be recycled by separating them before dumping at authorized...

Page 34: ...contents of this manual may be changed at any time and without notice Translation of the original instructions Page 34 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original instructions ...

Page 35: ...contents of this manual may be changed at any time and without notice Translation of the original instructions Page 35 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original instructions ...

Page 36: ... 4941 Page 36 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Page 36 Manual FA01358 EN 07 2019 CAME S p A The contents of this manual may be changed at any time and without notice Original instructions ...

Reviews: