F30
Slow-down
speed
Setting the door's opening and closing slow-down speed, calculated as a
percentage.
20
= Minimum speed /
40
= 40% of the motor's speed
(default)
/
60
=
Maximum speed
F33
Calibration
speed
Setting the gear motor's calibration speed, calculated as a percentage.
30
= 30% of the maximum speed /… /
50
= 50% of the maximum speed
(default)
/… /
60
= 60% of the maximum speed
F34
Travel
sensitivity
Adjusting obstruction detection sensitivity during door travel.
10
= Maximum sensitivity /… /
100
= Minimum sensitivity
(default)
F35
Slow-down
sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10
= Maximum sensitivity /… /
100
= Minimum sensitivity
(default)
F36
Adjusting the
partial opening
Adjusting, as a percentage of total door travel, the door's partial opening.
10
= 10% of the door travel /… /
40
= 40% of the door travel
(default)
/…
/
80
= 80% of the door travel
F41
Adjusting the
opening slow-
down
Percentage adjustment of the total door travel, of the opening slow-down
starting point.
1
= 1% of the door travel / … /
5
= 5% of the door travel
(default)
/ … /
60
= 60% of the door travel
F42
Adjusting the
closing slow-
down
Percentage adjustment of the total door travel, from the closing slow-down
starting point.
1
= 1% of the door travel / … /
15
= 15% of the door travel
(default)
/ … /
60
= 60% of the door travel
F44
Adjusting
the closing
approach
Adjusting, as a percentage of the total door travel, of the closing approach
starting point.
1
= 1% of the door travel / … /
10
= 10% of the door travel
(default)
F47
Slowed-down
start when
closing
Adjusting, as a percentage of the total door travel, of the starting of the closing
slow-down.
OFF
= Deactivated /
1
= 1% of the door travel (minimum) / … /
5
= 5% of the
door travel
(default)
/ … /
50
= 50% of the door travel (maximum)
F49
Managing
the serial
connection
For enabling the CRP (Came Remote Protocol).
0
= Deactivated /
3
= CRP
(default)
F50
Saving data
Saving users and settings saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the
control board.
0
= Deactivated (
default
) /
1
= Activated
F51
Uploading date
Uploading data saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the