TROUBLESHOOTING

Symptoms caused

Problem/error

Solution

No LEDs on.

The unit will not power up. 

Check power supply voltage at the PCB intercom is 24V DC. Check 
the fuse.

The unit powers up 
but the LED is still 
flashing rapidly

This means the unit is not 
able to detect the network 
for some reason.

This means the unit is not able to detect the network for some 
reason.
-Power off the unit, remove the SIM and check it in a mobile phone 
to verify it can make a call and has calling credit if it is a Pay As You 
Go SIM.
-Disable any PIN code request if active on the SIM card.
-Check the SIM is a standard voice capable SIM. If you are unsure, 
contact your SIM card provider to verify.
-Check the reception is medium or good. Poor reception is not 
sufficient.

-

Change to an external antenna

.

External Antenna Details

-Ensure the cable does not have too many sharp bends.
-Check the height of the antenna and make sure it is not inside a 
metal enclosure.
-Check correct power cable size for cable length from PSU. Refer to 
manual for guidelines

The caller ID function 
does not work.

Incorrect programming or 
poor signal

If your number is a private or number withheld, then it will not 
work.
-Ensure the number is programmed as you would normally dial it 
from another phone.
- Ensure you have adequate GSM signal at the intercom by sending 
*20# as a text.

Reset / Default Unit

1) Power off the unit. (approx 60 secs)

2) Make a link across the terminals 
marked OPEN.

3) Switch on power

4) After several seconds, the relay will 
click.

5) The unit will then clear memory and 
be defaulted

6) Remove the link and wait around 20 
seconds.

Note: 

Performing this process will 

remove all current programming.

This product is not a complete product until fully installed. It is therefore 

considered a component part of an overall system. The installer is responsible to 
check that the end installation complies with local regulatory requirements. This 

equipment forms part of a “fixed installation”.

STILL HAVING TROUBLE? 

Find all of our support options such as Web Chat, Full Manuals, Customer 

Helpline and more on our website:

WWW.AESGLOBALUS.COM

+1 (321) 900 4599

FCC ID : 2ALPX-PRIME7-4GQA

EUT : CellCOM Prime 7 4G

Test Model : PRIME7-PX-IMPK-PED/4GA

Additional Model No. PRIME7-IMP-PED/4GA, PRIME7-PX-IMP-PED/4GA, PRIME7-IMPK-PED/4GA, PRIME7-PX-IMPK-PED/4GA, 
PRIME7-AB/4GA, PRIME7-PX-AB/4GA, PRIME7-ABK/4GA, PRIME7-PX-ABK/4GA

Grantee: Advanced Electronic Solutions Global LLC

This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation. 

Output power listed is ERP below 1GHz for Part 22 and EIRP above 1GHz for Part 24. RF
exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used
for this transmitter must be installed to provide a separation distance of at least 20 cm from
all persons. 

End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

101

101

8.

00

0

RELAY

iGate 1200

OPEN 

Terminals

- GSM Gate Opener

STILL HAVING TROUBLE? 

Find all of our support options such as Web Chat, 

Full Manuals, Customer Helpline and more on 

our website:

WWW.AESGLOBALUS.COM

iGate 1200

Reviews: