background image

Summary of Contents for BAPPU-evo

Page 1: ......

Page 2: ...EN The original operating manual is in German Status 08 2019...

Page 3: ...s 9 Specifications of the measurement with VOCOO sx 10 Available sensors in VOCOO sx 10 Specifications for noise level measurement 10 Frequency weighting and permissible errors 11 Using the optional n...

Page 4: ...measuring range 21 6 2 Measurement result overview 21 6 3 Detailed view 22 6 4 Repeat measurement 22 7 Long term recording 23 7 1 Selecting the measuring range 23 7 2 Adjusting the interval settings...

Page 5: ...Starting the programme 35 10 4 Computer test 35 10 5 Working with BAPPU time 35 10 6 Operating and reading the internal data counter 36 Data Logger port 36 Configuring the data logger 36 Reading the B...

Page 6: ...send to support bappu de Copyright The copyright to this documentation remains at ELK GmbH The instructions for use contain the most important information for operating the product safely The instruct...

Page 7: ...Security alert During assembly and operation the following safety instructions must be observed Use personal protective equipment PPE When using the product it may be necessary to wear safety shoes Wh...

Page 8: ...nts or for measurements within the calibrated or permissible measuring range For measurements outside the calibrated range readings may be outside the allowable tolerance measuring unintended readings...

Page 9: ...8 Initial assembly The initial assembly and all related work will be carried out by the manufacturer 1 9 Delivery contents BAPPU evo comes equipped with an integrated data counter for long term recor...

Page 10: ...factory calibration of the unit should be carried out every twelve months BAPPU evo displays a corresponding message in the main menu one month before the end of the calibration interval This can be d...

Page 11: ...brightness Luminance contrast 10 2000 cd qm 1 60 60 1 under typical workplace lighting conditions 10 f MV 10 cd qm as for the luminance Silicon photo element with adapted spectral sensitivity 0 1 cd q...

Page 12: ...of the microphone Accoustic centre Centre of microphone diaphragm Screen refresh 0 33 s The noise level measurement values are made using frequency weighting A For carrying out frequency weightings s...

Page 13: ...ator before and after the measurement has been made In order to recalibrate BAPPU evo please follow the following steps When you are in the process of using the measurement designation Noise to take a...

Page 14: ...h the key a dew point calculation is available This is calculated on the basis of the determined measured values of air temperature and relative humidity At the dew point temperature the maximum satur...

Page 15: ...y of the rechargeable batteries The charging state of the battery is indicated on BAPPU evo screen by the battery icon that gradually fills up Tip Tip The charging will commence approximately one minu...

Page 16: ...l work places please refer to page 18 Modifying the measurement profile Profile The measurement sequence profile gives the user the opportunity to switch individual measuring ranges on or off Up to ni...

Page 17: ...tion In order to be able to utilise the data that has been recorded you will need to purchase a licence for BAPPU time software 3 Operating instructions 3 1 Display and touch screen The device feature...

Page 18: ...ver Kensington compatible 3 4 Help bar The help bar which is at the top edge of the screen describes the keyboard functions that are available The function of the right left and up down arrow keys as...

Page 19: ...overview of the current measurement values The Edit softkey is used for editing the work place name and the type of work place as well as the measurement sequence profile Tip Tip The current view does...

Page 20: ...ordance with your needs Tip Tip Measuring ranges from external sensors which are not connected do not appear in the measurement sequence even in cases when they are activated In order to be able to ed...

Page 21: ...e names and type definition data retrieval Editing the work place type can be carried out only using BAPPU Standard software Assigning a work place name Enter workplace name To assign a name select Na...

Page 22: ...o start measuring press According to the profile selected you will now start your first measurement By default this will be the measurement of the air temperature Tip Tip Work places that are marked w...

Page 23: ...vated by pressing hold The hold button activates a countdown that shows the time until the measurement value is recorded When the measurement is complete the user can change to the next measuring rang...

Page 24: ...comprises two screens Pressing the keys calls up the first screen of the following work place Keying in delete will delete all of the measured values from the current work place 6 3 Detailed view Deta...

Page 25: ...ed data The measuring range that is selected in the measurement sequence symbol list and that is indicated with the symbol will only be shown in the preview screen The lower part of the screen shows y...

Page 26: ...ng can be stopped by pressing Stop F3 or when the memory capacity is reached The data can be read using the optional BAPPU time software please refer to page 36 chapter 10 6 Operating and reading the...

Page 27: ...will influence the values being measured therefore it is important for the housing to have the same temperature as that of the ambient air For BAPPU this means that when a cold measuring device for e...

Page 28: ...are present in the work place definition are indicated These are clothing values for light clothing Summer middleweight clothing and heavy clothing Winter Please select the appropriate values that sho...

Page 29: ...symbol indicates that the data has been checked Press Start F3 to install the firmware update 8 6 User Init By selecting User Init the factory settings can be restored thus returning the device to th...

Page 30: ...ation with several multimeters BAPPU you need several licenses Licenses are only available from ELK GmbH ELK GmbH shall not assume any liability for any editorial or technical mistakes as well as the...

Page 31: ...riate device has been selected from the device list see figure to the left BAPPU evo is the default setting When the programme starts the software will suggest a possible path for the working director...

Page 32: ...l The set values can be entered in the Defining the type of work place dialog field This window can be opened by clicking the Type definition button in the main window Select the function Data new fro...

Page 33: ...desired values of the selected measurement range of the work place can be entered in the Set value of the display Target input field To display the PMV type definitions as well as the necessary clothi...

Page 34: ...es can be transferred from your PC to the BAPPU To begin a new project select File New or if you want to make any changes to an existing project use Open file When you want to make changes select the...

Page 35: ...For editing the tables please click either Definition 1 or Definition 2 In the Column selection section mark the value for the measurement you would like to view Apart from the user defined settings a...

Page 36: ...being transferred from the software to your BAPPU evo The profiles in your BAPPU evo will be overwritten If you want to save the profiles from your BAPPU evo click the Export from BAPPU button A dial...

Page 37: ...icense number that has been assigned to every BAPPU To register additional devices select Settings register additional BAPPU devices in the main menu Tip Tip When the license number has been entered a...

Page 38: ...APPU evo as shown in the diagram on the left Configuring the data logger The configuration window which is to be found in the main window is used for entering the settings for the measurement specific...

Page 39: ...cal gaps between two successive saved measurement values and thus the averaging time period This also affects the maximum amount of time available for the recording When the recording time increases m...

Page 40: ...mbine selected several marked recordings can be compiled into one piece of data as long as the data records required were recorded close together When Connect selection is selected the recordings will...

Page 41: ...o call up the dropdown menu or by clicking View Additional chart display in the main menu A graphic display can be marked by mouse click and replaced with a new graphic The new measurement range can b...

Page 42: ...a blue curve Display the minimum value with a green curve Display the maximum value with a red curve Tip Tip If you encounter problems displaying the data select View new graph in the menu list or pr...

Page 43: ...will return you to mark and move mode Ruler In mark and move mode you can use the moveable horizontal ruler in the graphic window to mark striking events and read all of the values of the measurement...

Page 44: ...ault the setting encompasses the calculation of the entire time frame of the recording If you want to display the average maximum and minimum values in the window select averages calculator You can sa...

Page 45: ...ime will give significant values and trends due to the fact that all of the measurement values are factored in during this time 10 12 Starting a recording After pressing the OK button the program will...

Page 46: ...w the current values Online Monitor During the recording it is possible to view the measurement trend in the data monitor as well as call up the data which has already been stored in the graphic windo...

Page 47: ...by clicking By clicking the measured values symbol in the top left hand side of the screen you can switch between the different measurement range views The end of the recording A recording will end w...

Page 48: ...ser a number of functions such as exchange images or show additional images Moreover it is possible to call up the file export function print a file and show the zoom functions 10 14 Guarantee BAPPU h...

Page 49: ...The operator has to ensure that all employees who handle the product have read and understood the instructions In addition he has to instruct the staff at regular intervals and inform them about the d...

Page 50: ...BAPPU evo Multi measuring device for workplace analysis 11 Notes page 48 compact manual status 07 2019...

Page 51: ......

Reviews: