C O N F I G U R A T I O N S C R E E N S
Light Tower Configuration
9-96
Bravo™ 8105 Programming and Operations Guide
Rev. 2
9
Light Tower Configuration
Introduction
The Light Tower is selected in Configure > Options. Select the “Configure Light
Tower” button to assign conditions to light states. More than one condition can
be assigned to a light state and more than one light state can be assigned to a
condition.
ATTENTION
Note that if a flashing state and a solid state of the same color are assigned to the
same condition, the solid color state overrides the flashing color state.
Software Screen
Figure 9–5
Light Tower Conditions
Unacknowledged Alarm
An alarm condition exists that has not been acknowledged. Press the
spacebar.
Acknowledged Alarms Exist
An alarm condition was acknowledged, but the state causing the alarm still
exists.
Manual Warm Up in Progress
The machine is in the process of reaching Ready state, but has not yet
reached it. Components are started individually in Manual Mode and only
those components turned On are functioning.