C O N F I G U R A T I O N S C R E E N S
Conveyor Parameters Configuration
2-9317-372-00-0
Bravo™ 8105 Programming and Operations Guide
9-101
Conveyor Parameters
Continued
IPC to OPC Length CM
Used by the optional Exit Photocell to track boards. It is the distance in
centimeters between the Load End Photocell and the Unload End (Exit)
Photocell.
Output PhotoCell Window in CM
The width in cm that is seen as an active window by the output photocell to
detect boards.
Additional Counts for OPC Jam Detection
The number of counts generated before an alarm sounds after the Photocell
expects to detect a PCB. It is used by the optional Exit Photocell.
Additional Length for Extended Cooling CM
The length in centimeters needed to mount the Output (Exit) Photocell if an
extended cooling module is installed on the machine. It is the distance
between the standard mount and the extended mount in centimeters.