ELECTRICAL & GAS CONNECTIONS
Models EFE914, EFEP916, EFEP956
27
8
673
95
168
Gas connection
point to regulator
Models: EFEP916,
EFE914
Electrical cable
entry point
Models:
EFEP916,
EFEP956,
EFE914
696
Gas hose restraints
point to regular
models: EFEP916,
EFE914
Installing the gas cooker
Gas pressures
The following table shows the supply and operating
pressures for various gases.
Gas type
Natural
gas
Universal
LPG
Supply pressure at inlet
to appliance regulator
1.13 (kPa)
Minimum
2.75
kPa
Operating pressure at
appliance test point
1.00 (kPa)
2.60 kPa
The following table shows the injector sizes for
each burner.
Injector Orifice
Natural gas Universal LPG
Low heat burner
1.00mm
0.55mm
Medium heat burner
1.35mm
0.70mm
High heat burner
1.60mm
0.90mm
Intense heat
dual wok burner
0.85mm
(inner)
2 x 1.25mm
(outer)
0.75mm
(inner)
2 x 1.60mm
(outer)
Checking piping size
To work out a suitable pipe size for connection use the
information in this table:
Model
Natural gas
Universal LPG
EFEP916
57.2 MJ/h
49.9 MJ/h
EFE914
57.2 MJ/h
49.9 MJ/h
For information and requirements about construction and
capacity of consumer piping refer to AS5601 series of
standards.
Gas connection
Read these points before connecting to the gas supply:
•
The appliance is preset for natural gas use. If LPG is
to be used see Conversion to LPG section.
•
Gas installation must be made in accordance with
AS5601, the local gas fitting regulations, municipal
codes and other statutory regulations.
•
The gas connection point is a ½” BSP external thread
located at the rear of the appliance as shown.
•
A regulator is supplied which must be fitted to the
appliance. Ensure that when fitted the pressure test
point of regulator is accessible.
•
The regulator is to be fitted to the manifold inlet at
the rear of the appliance and the connection thread
is sealed using a tape or jointing compound suitable
for gas connections. The consumer piping is then
connected to the inlet of the regulator, either:
1 directly, or
2 using a hose assembly and in accordance
with Clause 6.10.1.9 of AS 5601.1 (High level
connection) together with the supplied elbow.
The elbow is fitted to the inlet of the regulator
and oriented to allow the hose to hang
downwards. The connection thread between
the regulator and elbow is sealed using a
tape or jointing compound suitable for gas
connections.